Drug-Coated Balloon Versus Standard Percutaneous Transluminal Angioplasty for the Treatment of Superficial Femoral and Popliteal Peripheral Artery Disease

Author:

Tepe Gunnar1,Laird John1,Schneider Peter1,Brodmann Marianne1,Krishnan Prakash1,Micari Antonio1,Metzger Christopher1,Scheinert Dierk1,Zeller Thomas1,Cohen David J.1,Snead David B.1,Alexander Beaux1,Landini Mario1,Jaff Michael R.1

Affiliation:

1. From the RodMed Klinikum, Rosenheim, Germany (G.T.); UC Davis, Sacramento, CA (J.L.); Kaiser Permanente – Moanalua Medical Center and Clinic, Honolulu, HI (P.S.); Landeskrankenhaus – Universitätsklinikum, Graz, Austria (M.B.); The Mount Sinai Medical Center, New York, NY (P.K.); GVM Care and Research, Lugo, Italy (A.M.); Maria Eleonora Hospital, Palermo, Italy (A.M.); Wellmont Holston Valley Medical Center, Kingsport, TN (C.M.); Park-Krankenhaus Leipzig, Germany (D.S.); Universitäts-Herzzentrum...

Abstract

Background— Drug-coated balloons (DCBs) have shown promise in improving the outcomes for patients with peripheral artery disease. We compared a paclitaxel-coated balloon with percutaneous transluminal angioplasty (PTA) for the treatment of symptomatic superficial femoral and popliteal artery disease. Methods and Results— The IN.PACT SFA Trial is a prospective, multicenter, single-blinded, randomized trial in which 331 patients with intermittent claudication or ischemic rest pain attributable to superficial femoral and popliteal peripheral artery disease were randomly assigned in a 2:1 ratio to treatment with DCB or PTA. The primary efficacy end point was primary patency, defined as freedom from restenosis or clinically driven target lesion revascularization at 12 months. Baseline characteristics were similar between the 2 groups. Mean lesion length and the percentage of total occlusions for the DCB and PTA arms were 8.94±4.89 and 8.81±5.12 cm ( P =0.82) and 25.8% and 19.5% ( P =0.22), respectively. DCB resulted in higher primary patency versus PTA (82.2% versus 52.4%; P <0.001). The rate of clinically driven target lesion revascularization was 2.4% in the DCB arm in comparison with 20.6% in the PTA arm ( P <0.001). There was a low rate of vessel thrombosis in both arms (1.4% after DCB and 3.7% after PTA [ P =0.10]). There were no device- or procedure-related deaths and no major amputations. Conclusions— In this prospective, multicenter, randomized trial, DCB was superior to PTA and had a favorable safety profile for the treatment of patients with symptomatic femoropopliteal peripheral artery disease. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique Identifiers: NCT01175850 and NCT01566461.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine