Assessment of perinodular stiffness in differentiating malignant from benign thyroid nodules

Author:

Hu Lei1,Liu Xiao1,Pei Chong2,Xie Li1,He Nianan1

Affiliation:

1. 1Department of Ultrasound, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, China

2. 2Department of Respiratory and Critical Care Medicine, The First People’s Hospital of Hefei City, The Third Affiliated Hospital of Anhui Medical University, Hefei, Anhui, China

Abstract

Objective We evaluated the diagnostic accuracy of perinodular stiffness, four risk stratification systems (RSSs) (KWAK-TIRADS, ACR-TIRADS, EU-TIRADS, and C-TIRADS), and the combination of perinodular stiffness and the four RSSs in differentiating malignant from benign thyroid nodules (TNs). Methods A total of 788 TNs in 726 patients were examined with conventional ultrasound (US) examination and sound touch elastography (STE). All TNs were classified by each of the four RSSs. The stiffness inside (E) the TNs was measured by STE. The stiffness of the 2.0-mm perinodular region (Eshell) was measured with the Shell measurement function of STE. The diagnostic performances of four RSSs, the E values, and the Eshell values were evaluated. All TNs were further divided into subgroups based on size (≤ 10 mm group and > 10 mm group). Results Ninety-six TNs were classified as benign and 692 as malignant. Among the single-method approaches, ACR-TIRADS showed the highest AUC (0.77) for differentiating malignant from benign TNs for all TNs included. Eshell showed the highest AUC (0.75) in differentiating malignant from benign TNs for TNs with sizes ≤ 10 mm, and there were no significant differences in AUC among all single methods for diagnosis of TNs with sizes > 10 mm (P > 0.05). The combination of C-TIRADS and Eshell/E yielded the highest AUC for all TNs (0.83) and for TNs with size ≤ 10 mm (0.85) compared with other combinations. Conclusions Eshell/E combined with conventional US improves the diagnostic accuracy in TNs and may reduce unnecessary fine-needle aspiration.

Publisher

Bioscientifica

Subject

Endocrinology,Endocrinology, Diabetes and Metabolism,Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3