A portable spectroscopic instrument for multiplexed monitoring of acute water toxicity: Design, testing, and evaluation

Author:

Banerjee Amrita1,Singh Soumendra23,Ghosh Ria4,Hasan Md. Nur4,Bera Arpan4,Roy Lopamudra25,Bhattacharya Neha46,Halder Animesh2ORCID,Chattopadhyay Arpita7,Mukhopadhyay Subhadipta1ORCID,Das Amitava89,Altass Hatem M.10,Moussa Ziad11,Ahmed Saleh A.1012,Pal Samir Kumar4ORCID

Affiliation:

1. Department of Physics, Jadavpur University, 188, Raja S. C. Mallick Rd., Kolkata 700032, India

2. Technical Research Centre, S. N. Bose National Centre for Basic Sciences, Block JD, Sector III, Salt Lake, Kolkata, West Bengal 700106, India

3. Neo Care, Inc., 9 Parkstone Road, Dartmouth, Nova Scotia B3A 4J1, Canada

4. Department of Chemical, Biological and Macromolecular Sciences, S. N. Bose National Centre for Basic Sciences, Block JD, Sector 3, Salt Lake, Kolkata 700106, India

5. Department of Applied Optics and Photonics, University of Calcutta, 92, Acharya Prafulla Chandra Rd., Machuabazar, Kolkata 700009, India

6. Department of Radio Physics and Electronics, University of Calcutta, 92, Acharya Prafulla Chandra Rd., Machuabazar, Kolkata 700009, India

7. Department of Basic Science and Humanities, Techno International New Town, Block, DG 1/1, Action Area 1 New Town, Rajarhat, Kolkata 700156, India

8. Indian Institute of Science Education and Research Kolkata, Mohanpur 741246, WestBengal, India

9. Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India

10. Chemistry Department, Faculty of Applied Science, Umm Al-Qura University, 21955 Makkah, Saudi Arabia

11. Department of Chemistry, College of Science, United Arab Emirates University, P. O. Box 15551, Al Ain, Abu Dhabi, United Arab Emirates

12. Chemistry Department, Faculty of Science, Assiut University, 71516 Assiut, Egypt

Abstract

The deteriorating water environment worldwide, mainly due to population explosion and uncontrolled direct disposal of harmful industrial and farming wastes, earnestly demands new approaches and accurate technologies to monitor water quality before consumption overcoming the shortcomings of the current methodologies. A spectroscopic water quality monitoring and early-warning instrument for evaluating acute water toxicity are the need of the hour. In this study, we have developed a prototype capable of the quantification of dissolved organic matter, dissolved chemicals, and suspended particulate matter in trace amounts dissolved in the water. The prototype estimates the water quality of the samples by measuring the absorbance, fluorescence, and scattering of the impurities simultaneously. The performance of the instrument was evaluated by detecting common water pollutants such as Benzopyrene, Crystal Violet, and Titanium di-oxide. The limit of detection values was found to be 0.50, 23.9, and 23.2 ppb (0.29 µM), respectively.

Funder

Indian National Academy of Engineering

Publisher

AIP Publishing

Subject

Instrumentation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3