Fiber-tip endoscope for optical and microwave control

Author:

Dix Stefan1,Gutsche Jonas1,Waller Erik12,von Freymann Georg12ORCID,Widera Artur1ORCID

Affiliation:

1. Department of Physics and State Research Center OPTIMAS, University of Kaiserslautern, Erwin-Schroedinger-Str. 46, 67663 Kaiserslautern, Germany

2. Fraunhofer Institute for Industrial Mathematics ITWM, Fraunhofer-Platz 1, 67663 Kaiserslautern, Germany

Abstract

We present a robust, fiber-based endoscope with a silver direct-laser-written structure for radio frequency (RF) emission next to the optical fiber facet. Thereby, we are able to excite and probe a sample, such as nitrogen-vacancy (NV) centers in diamond, with RF and optical signals simultaneously and specifically measure the fluorescence of the sample fully through the fiber. At our targeted frequency range of around 2.9 GHz, the facet of the fiber core is in the near-field of the RF-guiding silver structure, which comes with the advantage of an optimal RF intensity decreasing rapidly with the distance. By creating a silver structure on the cladding of the optical fiber, we achieve the minimal possible distance between an optically excited and detected sample and an antenna structure without affecting the optical performance of the fiber. This allows us to realize a high RF amplitude at the sample’s position when considering an endoscope solution with integrated optical and RF access. The capabilities of the endoscope are quantified by optically detected magnetic resonance (ODMR) measurements of an NV-doped microdiamond that we probe as a practical use case. We demonstrate a magnetic sensitivity of our device of 17.8 nT[Formula: see text] when measuring the ODMR exclusively through our fiber and compare the sensitivity to a measurement using a confocal microscope. Moreover, the application of our device is not limited to NV centers in diamonds. Similar endoscope-like devices combining optical excitation and detection with radio frequency or microwave antenna could be used as a powerful tool for measuring a variety of fluorescent particles that have so far only been investigated with bulky and large optical setups. Furthermore, our endoscope points toward precise distance measurements based on Rabi oscillations.

Funder

Deutsche Forschungsgemeinschaft

Publisher

AIP Publishing

Subject

Instrumentation

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3