Design and implementation of an acoustic-vibration capacitive MEMS microphone

Author:

Duanmu Zheng1ORCID,Kong Chunxiu2,Guo Yangkuan1,Zhang Xiaoqing1,Liu Hongzhi3,Zhao Chenglong3,Gong Xiaofeng3,Cai Chunhua3,Ho Chenta3,Wan Caixin3ORCID

Affiliation:

1. Key Laboratory of the Ministry of Education for Optoelectronic Measurement Technology and Instrument, Beijing Information Science and Technology University, Beijing, China

2. School of Optoelectronics, Beijing Institute of Technology, Beijing, China

3. Wuxi Willmems Semiconductor Co., Ltd., Wuxi, Jiangsu, China

Abstract

A novel acoustic-vibration capacitive microelectromechanical system microphone is designed, fabricated, and implemented in this paper. The new microphone consists of a rigid diaphragm and mass blocks sensitive to low-frequency vibratory and sound signals. This sensor takes advantage of the semiconductor technology to design the capacitance sensor structure by surface micromachining technology, and the inertial mass blocks are shaped using the bulk silicon micromachining technology. The structure of the anti-stiction-dimple array is designed and deployed at the bottom of the diaphragm and the backplate to avoid the risk of sensor failure by vibration stiction. The bottom and top of the backplate are designed with an anti-humidity hydrophobic insulation protective layer, which avoids adsorption of moisture and attachment of foreign particles. The thickness of the mass blocks can be controlled by the combination of the dry and the wet micromachining method, which is sensitive to different frequency responses. This study can design and produce wafer level silicon with high consistency. The inertial mass proposed in this research can be achieved through a 6 in. wafer process with >80% consistency when the thickness of the mass is around 300 μm. The sensing frequency can be reduced to below the 4 kHz frequency bandwidth with enhanced sensitivity in the ±0.5 dB range. Typical characteristic results show that the open-circuit sensitivity of the microphone is 12.63 mV/Pa (37.97 dBV/Pa) at 1 kHz (with 94 dB as the reference sound level). The total harmonic distortion and acoustic overload point are 0.21% and 121.2 dB sound pressure level, respectively. The electronic stethoscope is a typical application of this research, which can collect the characteristics and frequency spectrum of low-frequency cardiac vibration signals.

Funder

The National Key Research and DevelopmentProgram of China

Publisher

AIP Publishing

Subject

General Physics and Astronomy

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3