Abstract
For the flow field distribution and control mechanism generated by the electrohydrodynamics (EHD) system with multi-needle corona discharge, this paper takes the multi-needle EHD pump as the research object, establishes different types of physical models through regional division, constructs multi-physical field coupling relationship, and derives a simplified EHD flow velocity equation suitable for the EHD system with multi-needle corona discharge. Combined with the intelligent optimization method of population evolution, a novel and effective intelligent algorithm is designed for the numerical analysis of the velocity profile distribution of a multi-needle EHD pump, and the flow velocity control law of the multi-needle EHD pump is analyzed by quantitative calculation. The validity of the model and analysis is verified by the electric field and flow field simulation of the multi-needle EHD pump system. The calculation results show that the voltage parameter is more dominant than the electrode spacing parameter in the steady-state flow velocity control of the multi-needle EHD pump, and both the maximum flow velocity and the average flow velocity are superlinearly controlled by voltage. In the design of multi-needle EHD pump with an electrode spacing of 1 cm, the simulation results show that the maximum gas flow velocity of 0.82 m/s can be obtained by providing 5000 V voltage, which verifies the design of a miniaturized multi-needle EHD pump and its feasibility in gas lasers and other application scenarios.
Funder
Youth Innovation Promotion Association of the Chinese Academy of Sciences
Key Basic Research Projects of the Basic Strengthening Plan
Scientific Instrument Developing Project of the Chinese Academy of Sciences