Abstract
ABSTRACTThe purpose of the study was to evaluate three real-time PCR platforms for rapid detection of Salmonella from cloves and to compare three different DNA extraction methods. Six trials were conducted with two clove cultivars, Ceylon and Madagascar, and three Salmonella serotypes, Montevideo, Typhimurium, and Weltevreden. Each trial consisted of 20 test portions. The preenrichment cultures were used to perform PCR for comparison of the effectiveness of U.S. Food and Drug Administration, Pacific Regional Laboratory Southwest (FDA-PRLSW), Applied Biosystems Inc. (ABI) MicroSEQ, and GeneDisc platforms for detection of Salmonella. Three DNA extraction methods were used: standard extraction method for each PCR platform, boil preparation, and LyseNow food pathogen DNA extraction cards. The results from real-time PCR correlated well with FDA Bacteriological Analytical Manual culture assay results, with a wide range of cycle threshold (CT) values among the three PCR platforms for intended positive samples. The mean CT values for MicroSEQ (16.36 ± 2.78) were significantly lower than for PRLSW (20.37 ± 3.45) and GeneDisc (23.88 ± 2.90) (P < 0.0001). Pairwise comparisons between PCR platforms using different DNA extraction methods indicate that the CT values are inversely proportional to the relative DNA quantity (RDQ) yields by different platform-extraction combinations. The pairing of MicroSEQ and boil preparation generated the highest RDQ of 120 and the lowest average CT value of 14.48, whereas the pairing of GeneDisc and LyseNow generated the lowest RDQ of 0.18 and the highest average CT of 25.97. Boil preparation yielded higher RDQ than the other extraction methods for all three PCR platforms. Although the MicroSEQ platform generated the lowest CT values, its sensitivity was compromised by narrow separations between the positive and negative samples. The PRLSW platform generated the best segregation between positive and negative groups and is less likely to produce false results. In conclusion, FDA-PRLSW was the most efficient PCR assay for Salmonella detection, and boil preparation was the best method for DNA extraction.
Publisher
International Association for Food Protection
Subject
Microbiology,Food Science
Reference27 articles.
1. Antimicrobial activity of spices;Arora,;Int. J. Antimicrob. Agents,1999
2. Evaluation of applied biosystems MicroSEQ real-time PCR system for detection of Salmonella spp. in food;Balachandran,;J. AOAC Int,2011
3. Microbiological quality of some retail spices in India;Banerjee,;Food Res. Int,2002
4. Evaluation of the “GeneDisc” real-time PCR system for detection of enterohaemorrhagic Escherichia coli (EHEC) O26, O103, O111, O145 and O157 strains according to their virulence markers and their O- and H-antigen-associated genes;Beutin,;J. Appl. Microbiol,2009
5. Salmonella Montevideo infections associated with salami products made with contaminated imported black and red pepper—United States, July 2009–April 2010;Centers for Disease Control and Prevention (CDC);Morb. Mortal. Wkly. Rep,2010
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献