Microbead-Based Immunoassay for Simultaneous Detection of Shiga Toxins and Isolation of Escherichia coli O157 in Foods

Author:

CLOTILDE LAURIE M.1,BERNARD CLAY1,HARTMAN GARY L.2,LAU DAVID K.2,CARTER J. MARK1

Affiliation:

1. 1Western Regional Research Center, Agricultural Research Service, U.S. Department of Agriculture, Albany, California 94710

2. 2U.S. Food and Drug Administration, Alameda, California 94502, USA

Abstract

Shiga toxin–producing Escherichia coli (STEC) is a significant foodborne pathogen with great economic consequences. There has been an increased food safety concern with this organism since outbreaks of human illnesses caused by this pathogen were first reported in 1982. Therefore, developing a reliable, sensitive, and rapid assay capable of detecting E. coli O157 and the main toxins produced by STEC (i.e., Shiga toxins 1 [Stx1] and 2 [Stx2]) will directly benefit regulatory agencies by minimizing analysis time. Here, we use Luminex technology to detect multiple analytes in a single 50-ml sample. Using commercially available monoclonal antibodies coupled to carboxylated magnetic microbeads, we developed an immunoassay capable of simultaneously serotyping E. coli O157 and detecting Stx1 and/or Stx2. The specificity and sensitivity of this immunoassay was tested against a collection of 34 E. coli isolates belonging to various O serogroups phenotypically different for Stx. The results were compared with microplate sandwich enzyme-linked immunosorbent assay (ELISA), and no cross-reactivity was observed for any of the monoclonal antibodies used. An increased sensitivity up to 1,000 times was observed in the microbead-based immunoassay when compared with the microplate sandwich ELISA. The results indicate that Luminex technology has the potential to simultaneously detect multiple targets without loss of specificity and/or sensitivity. A blind experiment was conducted with 48 samples of ground beef, lettuce, and milk spiked with ≤2 CFU/g E. coli. All the samples were correctly identified, with no false positives or false negatives. This microbead-based immunoassay could be extended to simultaneously detect additional foodborne pathogens and their toxic markers.

Publisher

International Association for Food Protection

Subject

Microbiology,Food Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3