Abstract

Objective: to construct geometric models of carotid bifurcation and build a computer modeling for carotid endarterectomy (CEA) operations with patches of various configurations.Materials and methods. The method uses reconstructed models of a healthy blood vessel obtained from a preoperative computed tomography (CT) study of the affected blood vessel of a particular patient. Flow in the vessel is simulated by computational fluid dynamics using data from the patient's ultrasonic Doppler velocimetry and CT angiography. Risk factors are assessed by hemodynamic indices at the vessel wall associated with Wall Shear Stress (WSS).Results. We used the proposed method to study the hemodynamic results of 10 virtual CEA operations with patches of various shapes on a reconstructed healthy artery of a particular patient. The reason for patch implantation was to ensure that the vessel lumen is not narrowed as a result of the surgery, since closing the incision without a patch can reduce the vessel lumen circumference by 4–5 mm, which adversely affects blood flow. On the other hand, too wide a patch creates aneurysmorphic deformation of the internal carotid artery (ICA) mouth, which is not optimal due to formation of a large recirculation zone. In this case, it was found that the implanted patch width of about 3 mm provides an optimal hemodynamic outcome. Deviations from this median value, both upward and downward, impair hemodynamics. The absence of a patch gives the worst of the results considered.Conclusion: The proposed computer modeling technique is able to provide a personalized patch selection for classical CEA with low risk of restenosis in the long-term follow-up.

Publisher

V.I. Shimakov Federal Research Center of Transplantology and Artificial Organs

Subject

Transplantation,Immunology and Allergy

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Update in Carotid Disease;Current Problems in Cardiology;2023-06

2. Long-term results conventional and eversion carotid endarterectomy;Zhurnal nevrologii i psikhiatrii im. S.S. Korsakova;2023

3. Carotid endarterectomy in Russia. What if current guidelines do not answer difficult questions?;Russian Journal of Cardiology;2022-12-02

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3