The Use of Intraoperative Aberrometry in Normal Eyes: An Analysis of Intraocular Lens Selection in Scenarios of Disagreement

Author:

Greenwood Michael D.,Hutchison Jake W.,Gorham Richard A.,Kramer Brent A.

Abstract

PURPOSE: To compare prediction error outcomes between the Optiwave Refractive Analysis System (ORA) (Alcon Laboratories, Inc) and two modern intraocular lens (IOL) formulas (Hill-RBF2.0 [HRBF] and Barrett Universal II [BUII]), and further analyze IOL selection in scenarios of disagreement between methods. METHODS: Patients with no previous history of corneal refractive surgery who underwent cataract extraction and had intraoperative aberrometry measurements between October 2016 and December 2019 were analyzed. The prediction error for the ORA, HRBF, and BUII were calculated based on the postoperative manifest refraction. Further analysis was performed evaluating prediction error for scenarios of disagreement between the three methods. RESULTS: After exclusions, 281 eyes were included. The mean absolute prediction errors were 0.28 diopters (D) (ORA), 0.31 D (HRBF), and 0.33 D (BUII) ( P < .05). In instances when the IOL recommended by the ORA was in disagreement with what was selected preoperatively, there was no benefit when the lens recommended by the ORA was selected based on anecdotal experience. When further analyzing these instances of disagreement, selecting the ORA-recommended lens when it is higher in power results in improved refractive outcomes: the ORA resulted in more eyes within ±0.25 diopters (D) of predicted spherical error (65% ORA, 37% HRBF, 32% BUII; P = .004) and fewer hyperopic surprises (5% ORA, 15% HRBF, 24% BUII; P = .009). CONCLUSIONS: In normal eyes without previous corneal refractive surgery, intraoperative aberrometry is not different from to two modern preoperative IOL formulas. Placing the ORA-recommended lens when it is higher in power than that selected preoperatively results in better refractive outcomes. [ J Refract Surg . 2022;38(5):304–309.]

Publisher

SLACK, Inc.

Subject

Ophthalmology,Surgery

Reference27 articles.

1. The changing pattern of cataract surgery indications: a 5-year study of 2 cataract surgery databases;Lundström M;Ophthalmology,2015

2. [A method of calculating the optical power of the intraocular lens];Fedorov SN;Vestn Oftalmol,1967

3. Calculation of the power of an iris clip lens for distant vision.

4. The optical design of intraocular lens implants;Binkhorst RD;Ophthalmic Surg,1975

5. The Emmetropic and the Iseikonic Implant Lens: Computer Calculation of the Refractive Power and its Accuracy

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3