Accuracy of intraoperative aberrometry versus modern preoperative methods in post-myopic laser vision correction eyes undergoing cataract surgery with capsular tension ring placement

Author:

Chen Allison J.,Long Christopher P.,Lu Tianlun,Garff Kevin J.,Heichel Christopher W.ORCID

Abstract

Abstract Purpose To assess the accuracy of intraoperative wavefront aberrometry (IWA) versus modern intraocular lens formulas in post-myopic laser vision correction (LVC) patients undergoing cataract surgery with capsular tension ring placement. Methods This is a retrospective chart review conducted at an academic outpatient center. All post-myopic LVC eyes undergoing cataract surgery with IWA from a single surgeon from 05/2017 to 12/2019 were included. All patients received a capsular tension ring (CTR). Mean numerical error (MNE), median numerical error (MedNE), and percentages of prediction error within 0.50D, 0.75D, and 1.00D were calculated for the above formulas. Results Twenty-seven post-myopic LVC eyes from 18 patients were included. In post-myopic LVC, MNE with Optiwave Refractive Analysis (ORA), Barrett True K (BTK), Haigis, Haigis-L, Shammas, SRK/T, Hill-RBF v3.0, and W-K AL-adjusted Holladay 1 were + 0.224, − 0.094, + 0.193, − 0.231, − 0.372, + 1.013, + 0.860, and + 0.630 (F = 8.49, p < 0.001). MedNE were + 0.125, − 0.145, + 0.175, + 0.333, + 0.333, + 1.100, + 0.880, and + 0.765 (F = 7.89, p < 0.001), respectively. BTK provided improved accuracy in both MNE (p < 0.001) and MedNE (p = .033) when compared to ORA in pairwise analysis. If the ORA vs. BTK-suggested IOL power were routinely selected, 30% and 15% of eyes would have projected hyperopic outcomes, respectively (p = 0.09). Conclusions Our study suggests that in post-myopic LVC eyes undergoing cataract surgery with CTRs, BTK performed more accurately than ORA with regard to accuracy and yielded a lower percentage of eyes with hyperopic outcomes. Haigis, Haigis-L, and Shammas yielded similar results to ORA with regard to accuracy and percentage of eyes with hyperopic outcomes. On average, Shammas and Haigis-L suggested IOLs that would yield outcomes more myopic than expected when compared to BTK.

Publisher

Springer Science and Business Media LLC

Subject

Cellular and Molecular Neuroscience,Sensory Systems,Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3