EFFECT OF GROWING YEAR AND APPLICATION OF A MULTI-YEAR CALIBRATION FOR PREDICTING QUALITY PARAMETERS BY NEAR INFRARED REFLECTANCE SPECTROSCOPY IN WHOLE-PLANT CORN FORAGE

Author:

VALDES E. V.,JONES G. E.,HOEKSTRA G. J.

Abstract

Near infrared reflectance spectroscopy analysis (NIRA) to predict quality parameters in whole-plant corn forage was investigated. Quality parameters studied included acid detergent fiber (ADF), in vitro dry matter digestibility (IVDMD) and crude protein (CP). Samples of whole-plant corn forage were collected during three growing years (1984, 1985, 1986) across six geographical locations in Ontario, Canada and were harvested at an average 35% dry matter content. Samples were randomly divided into two sets: a calibration (CAL) set to develop NIRA equations and a testing (TEST) set to validate these equations. NIRA calibrations for ADF, IVDMD and CP percent were performed for each growing season across locations. A multi-year calibration was also developed with samples drawn from the three growing years. The accuracy of the NIRA predictions was assessed by the standard error of the estimate (SEE), bias or the mean difference between laboratory and NIRA data, the coefficient of determination (r2) and the slope (b) of the regressions between laboratory and NIRA data. The single year calibrations showed good predictions for all quality parameters in samples drawn within the year. The SEE values in the TEST sets for single year calibrations varied from 1.6 to 1.9% for ADF, 1.5 to 2.3% for IVDMD and 0.3 to 0.5% for CP, respectively. However, recalibration was necessary every year because calibrations based on a single year failed to account for variances introduced by samples drawn from other years. The multi-year calibration predicted ADF, IVDMD and CP percent accurately regardless of year. The SEE and bias for ADF, IVDMD and CP percent for the TEST set were 1.6 and 0.1, 2.2 and 0.3, and 0.5 and 0.1, respectively. The success of the multi-year calibration encourage the possibility to develop a standard calibration for whole-plant corn.Key words: Near infrared reflectance analysis, calibrations, whole-plant corn forage, year, multi-year quality parameters

Publisher

Canadian Science Publishing

Subject

Horticulture,Plant Science,Agronomy and Crop Science

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3