Flow modification on the internal carotid artery bifurcation region and A1 segment after M1-internal carotid artery flow diverter deployment

Author:

Cagnazzo FedericoORCID,Ahmed Raed,Lefevre Pierre-HenriORCID,Derraz Imad,Dargazanli CyrilORCID,Gascou GregoryORCID,Riquelme Carlos,Frandon JulienORCID,Bonafe Alain,Costalat Vincent

Abstract

BackgroundClinical and hemodynamic consequences of flow diverters extending from the M1 to the internal carotid artery (ICA), covering the A1 segment, have rarely been investigated. We aimed to provide angiographic and clinical data about flow modifications on the covered A1.MethodsConsecutive patients receiving M1-ICA flow diverters for unruptured aneurysms were collected from our prospective database (2014–2020).Results42 A1 arteries covered with a single device were studied. All patients had an angiographic detected contralateral flow from the anterior communicating artery (AcomA). Immediately after flow diversion, 20 (47.6%) covered A1 showed slow flow. During a mean angiographic follow-up of 14 months, 13 (31%) and 22 (52.3%) A1 arteries were occluded and narrowed, respectively. Flow changes were asymptomatic in all cases. Vascular risk factors, sex, oversized compared with not oversized stents, immediate A1 slow flow, age, diameter of the A1, length of follow-up, and platelet inhibition rate were tested as prognosticators of A1 occlusion. Length of the angiographic follow-up was the only predictor of A1 occlusion (p=0.005, OR=3, CI=1.4 to 6.7). There were two device related ischemic events with a 2.3% rate of morbidity (one basal ganglia infarct after coverage of the M1 perforators and one transient acute instent thrombosis).ConclusionsCovering the A1 segment during M1-ICA flow diversion seems relatively safe, if the contralateral flow is assured by the AcomA. Approximately 31% and 52% of the covered A1 showed asymptomatic occlusions and narrowing, respectively. The likelihood of flow modification was proportional to the length of follow-up. Morbidity associated with flow diversion in the ICA terminus region was 2.3%.

Publisher

BMJ

Subject

Clinical Neurology,General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3