High-resolution CT with arch/neck/head CT angiography on a mobile stroke unit

Author:

Alexandrov Anne W,Arthur Adam S,Bryndziar Tomas,Swatzell Victoria M,Dusenbury Wendy,Hardage Keri,McCormick Sarah,Rhudy James P,Maleki Ana Hossein Zadeh,Singh SavdeepORCID,Krishnaiah Balaji,Nearing Katherine,Rubin Mark N,Malkoff Marc D,McKendry Christopher,Metter E Jeffrey,Alexandrov Andrei VORCID

Abstract

BackgroundMobile stroke units (MSUs) performance dependability and diagnostic yield of 16-slice, ultra-fast CT with auto-injection angiography (CTA) of the aortic arch/neck/circle of Willis has not been previously reported.MethodsWe performed a prospective observational study of the first-of-its kind MSU equipped with high resolution, 16-slice CT with multiphasic CTA. Field CT/CTA was performed on all suspected stroke patients regardless of symptom severity or resolution. Performance dependability, efficiency and diagnostic yield over 365 days was quantified.Results1031 MSU emergency activations occurred; of these, 629 (61%) were disregarded with unrelated diagnoses, and 402 patients transported: 245 (61%) ischemic or hemorrhagic stroke, 17 (4%) transient ischemic attack, 140 (35%) other neurologic emergencies. Total time from non-contrast CT/CTA start to images ready for viewing was 4.0 (IQR 3.5–4.5) min. Hemorrhagic stroke totaled 24 (10%): aneurysmal subarachnoid hemorrhage 3, hemorrhagic infarct 1, and 20 intraparenchymal hemorrhages (median intracerebral hemorrhage score was 2 (IQR 1–3), 4 (20%) spot sign positive). In 221 patients with ischemic stroke, 73 (33%) received alteplase with 31.5% treated within 60 min of onset. CTA revealed large vessel occlusion in 66 patients (30%) of which 9 (14%) were extracranial; 27 (41%) underwent thrombectomy with onset to puncture time averaging 141±90 min (median 112 (IQR 90–139) min) with full emergency department (ED) bypass. No imaging needed to be repeated for image quality; all patients were triaged correctly with no inter-hospital transfer required.ConclusionsMSU use of advanced imaging including multiphasic head/neck CTA is feasible, offers high LVO yield and enables full ED bypass.

Funder

Assisi Foundation of Memphis

Publisher

BMJ

Subject

Clinical Neurology,General Medicine,Surgery

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3