Abstract
BackgroundIndirect calorimetry (IC) is the gold standard for determining energy requirement. Due to lack of availability in many institutions, predictive equations are used to estimate energy requirements. The purpose of this study is to determine the accuracy of predictive equations (ie, Harris-Benedict equation (HBE), Mifflin-St Jeor equation (MSJ), and Penn State University equation (PSU)) used to determine energy needs for critically ill, ventilated patients compared with measured resting energy expenditure (mREE).MethodsThe researchers examined data routinely collected as part of clinical care for patients within intensive care units (ICUs). The final sample consisted of 68 patients. All studies were recorded during a single inpatient stay within an ICU.ResultsPatients, on average, had an mREE of 33.9 kcal/kg using IC. The estimated energy requirement when using predictive equations was 24.8 kcal/kg (HBE×1.25), 24.0 kcal/kg (MSJ×1.25), and 26.8 kcal/kg (PSU).DiscussionThis study identified significant differences between mREE and commonly used predictive equations in the ICU.Level of evidenceIII.
Subject
Critical Care and Intensive Care Medicine,Surgery
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献