Author:
Garcia-De la Rosa Guillermo,Olivo-Payne Andrew,Serna-Ojeda Juan Carlos,Salazar-Ramos Maria Sandra,Lichtinger Alejandro,Gomez-Bastar Arturo,Ramirez-Miranda Arturo,Navas Alejandro,Graue-Hernandez Enrique O
Abstract
ObjectiveTo assess anterior segment changes, including iridocorneal angle and vault, after toric and non-toric implantable collamer lens (ICL) V4c (STAAR Surgical AG) implantation under different lighting conditions.MethodsLongitudinal, prospective, case series. Patients with high myopia (>6 dioptres) underwent toric and non-toric ICL V4c implantation. Optical coherence tomography measurements were taken under different lighting conditions preoperatively and at 1 week and 1, 6 and 12 months of follow-up.ResultsSeventy-six eyes of 42 patients underwent ICL V4c implantation. Mean age was 27.4 years (±5.14 years, range 20 to 39 years). The average iridocorneal angle showed a statistically significant decrease (p<0.05) in all mesopic, scotopic and photopic conditions after 1 week of surgery compared with the preoperative measurements; in mesopic conditions, it decreased 14.1°, in photopic conditions 14.8° and scotopic conditions 13.2°. The angle measurement had a statistically significant change only in mesopic conditions (p=0.01) over the 1-year follow-up. The average vault under mesopic conditions was 0.661±0.21 mm at week 1. The vault measurement change was statistically significant over the 1-year follow-up in mesopic conditions (p=0.01). Refractive results showed a significant improvement in both uncorrected and corrected distance visual acuity (p<0.001).ConclusionThere is a significant reduction in the iridocorneal angle after ICL V4c implantation. Furthermore, there is a change under mesopic conditions in both the iridocorneal angle and vault during long-term follow-up.
Subject
Cellular and Molecular Neuroscience,Sensory Systems,Ophthalmology
Reference18 articles.
1. Implantable collamer lens—morphological changes induced in the anterior segment;Galveia;J Emmetropia,2012
2. Changes in vaulting and the effect on refraction after phakic posterior chamber intraocular lens implantation;Kamiya;J Cataract Refract Surg,2009
3. Phakic posterior chamber lenses for high myopia: functional and anatomical outcomes;Arne;J Cataract Refract Surg,2000
4. Posterior chamber collagen copolymer phakic intraocular lenses to correct myopia: five-year follow-up;Alfonso;J Cataract Refract Surg,2011
5. Comparison of surgical time and IOP spikes with two ophthalmic viscosurgical devices following Visian STAAR (ICL, V4c model) insertion in the immediate postoperative period;Ganesh;Clin Ophthalmol,2016
Cited by
36 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献