Prediction model of the horizontal trabecular iris angle after phakic posterior chamber implantable intraocular lens surgery

Author:

Sánchez-Trancón Angel,Manito Santiago Cerpa,Sierra Oscar TorradoORCID,Baptista António Manuel,Serra Pedro MiguelORCID

Abstract

Purpose: To determine the predictors of the postoperative horizontal trabecular iris angle (TIA750) after phakic posterior chamber implantable intraocular lens (IOL) surgery. Setting: Ophthalmology Clinic Vista Sánchez Trancón, Badajoz, Spain. Design: Retrospective case series. Methods: 330 eyes implanted with spherical/toric implantable collamer lens (ICL) were included in this study. From 230 eyes implanted with 13.2 mm ICL, these were divided in modeling (n = 180) and evaluation group (n = 50). Two groups implanted with 12.6 mm and 13.7 mm (n = 50 each) were also used as evaluation. Anterior-segment optical coherence tomography was used preoperatively to perform anterior chamber biometry (angle-to-angle [ATA] distance, crystalline lens rise, anterior chamber depth [ACD], cornea sagittal depth, pupil diameter, nasal/temporal TIA750); postoperatively for measuring the vault, pupil diameter and nasal/temporal TIA750. Corneal curvature and horizontal visible iris diameter were measured using optical tomography. Bivariate correlation analysis was used to determine associations between preoperative and postoperative horizontal TIA750 with anterior chamber biometry, ICL-related parameters and age. Finally, a multivariate linear regression model was constructed for predicting the postoperative TIA750. Results: Horizontal TIA750 reduced from 42.9 ± 8.0 degrees preoperatively to 24.4 ± 5.6 degrees postoperatively. Postoperative TIA750 was positively correlated with the preoperative TIA750, cornea sagittal depth and ACD, and negatively associated with the vault. The main predictors of the postoperative TIA750 were the preoperative parameters, TIA750, ICLsize − ATA and pupil diameter (adjusted-R 2 = 0.39). The limits of agreement between predicted and real TIA750 were close to ±10 degrees. Conclusions: Implantation of a phakic posterior chamber implantable IOL leads to a reduction in TIA750 and the main factors contributing for this are the preoperative TIA750 aperture and the vault.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Sensory Systems,Ophthalmology,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3