Contactless monitoring of respiratory rate (RR) and heart rate (HR) in non-acuity settings: a clinical validity study

Author:

Varma Muralidhar,Sequeira Trevor,Naidu Navaneetha Krishnan S,Mallya Yogish,Sunkara Amarendranath,Patil Praveen,Poojary Nagaraj,Vaidyanathan Manikanda Krishnan,Balmaekers BenoîtORCID,Thomas JosephORCID,Prasad N Shankar,Badagabettu SulochanaORCID

Abstract

ObjectivePatient monitoring in general wards primarily involves intermittent observation of temperature, heart rate (HR), respiratory rate (RR) and blood pressure performed by the nursing staff. Several hours can lapse between such measurements, and the patient may go unobserved. Despite the growing widespread use of sensors to monitor vital signs and physical activities of healthy individuals, most acutely ill hospitalised patients remain unmonitored, leaving them at an increased risk. We investigated whether a contactless monitoring system could measure vital parameters, such as HR and RR, in a real-world hospital setting.DesignA cross-sectional prospective study.Setting and participantsWe examined the suitability of employing a non-contact monitoring system in a low-acuity setup at a tertiary care hospital in India. Measurements were performed on 158 subjects, with data acquired through contactless monitoring from the general ward and dialysis unit.Outcome measuresVital parameters (RR and HR) were measured using a video camera in a non-acuity setting.ResultsThree distinct combinations of contactless monitoring afforded excellent accuracy. Contactless RR monitoring was linearly correlated with Alice NightOne and manual counts, presenting coefficients of determination of 0.88 and 0.90, respectively. Contactless HR monitoring presented a coefficient of determination of 0.91. The mean absolute errors were 0.84 and 2.15 beats per minute for RR and HR, respectively.ConclusionsCompared with existing Food and Drug Administration-approved monitors, the findings of the present study revealed that contactless monitoring of RR and HR accurately represented study populations in non-acuity settings. Contactless video monitoring is an unobtrusive and dependable method for monitoring and recording RR and HR. Further research is needed to validate its dependability and utility in other settings, including acute care.Trial registration numberCTRI/2018/11/016246.

Funder

Philips Research Bangalore, India

Publisher

BMJ

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3