Comparison between optical microscopy and automation for cytometric analysis of pericardial fluids in a cohort of adult subjects undergoing cardiac surgery

Author:

Buoro SabrinaORCID,Seghezzi MichelaORCID,Baigorria Vaca Maria del Carmen,Manenti Barbara,Moioli Valentina,Previtali Giulia,Simon Caterina,Cugola Diego,Brucato Antonio,Ottomano Cosimo,Lippi GiuseppeORCID

Abstract

AimsLimited information is available on number and type of cells present in the pericardial fluid (PF). Current evidence and has been garnered with inaccurate application of guidelines for analysis of body fluids. This study was aimed at investigating the performance of automate cytometric analysis of PF in adult subjects.MethodsSeventy-four consecutive PF samples were analysed with Sysmex XN with a module for body fluid analysis (XN-BF) and optical microscopy (OM). The study also encompassed the assessment of limit of blank, limit of detection and limit of quantitation (LoQ), imprecision, carryover and linearity of XN-BF module.ResultsXN-BF parameters were compared with OM for the following cell classes: total cells (TC), leucocytes (white blood cell [WBC]), polymorphonuclear (PMN) and mononuclear (MN) cells. The relative bias were −4.5%, 71.2%, 108.2% and −47.7%, respectively. Passing and Bablok regression yielded slope comprised between 0.06 for MN and 5.8 for PMN, and intercept between 0.7 for PMN and 220.3 for MN. LoQ was comprised between 3.8×106 and 6.0×106 cells/L for WBC and PMN. Linearity was acceptable and carryover negligible.ConclusionsPF has a specific cellular composition. Overall, automated cell counting can only be suggested for total number of cells, whereas OM seems still the most reliable option for cell differentiation.

Publisher

BMJ

Subject

General Medicine,Pathology and Forensic Medicine

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Recent advances in pericarditis;European Journal of Internal Medicine;2022-01

2. Performance evaluation of automated cell counts compared with reference methods for body fluid analysis;Diagnosis;2021-10-01

3. Automated cell count in body fluids: a review;Advances in Laboratory Medicine / Avances en Medicina de Laboratorio;2021-03-15

4. Adequate scattergram interpretation increases the reliability of automated polymorphonuclear (pmn) cell counts from ascitic fluid of patients with liver cirrhosis;International Journal of Laboratory Hematology;2021-02-19

5. El recuento automatizado de células en líquidos biológicos: una revisión;Advances in Laboratory Medicine / Avances en Medicina de Laboratorio;2021-02-11

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司