Standardisation of ACPA tests: evaluation of a new candidate reference preparation

Author:

Van Hoovels LieveORCID,Studholme Lucy,Vander Cruyssen Bert,Sieghart Daniela,Bonroy Carolien,Nagy Eszter,Pullerits Rille,Čučnik Sasa,Dahle Charlotte,Heijnen Ingmar,Bernasconi Luca,Benkhadra Farid,Bogaert Laura,Van Den Bremt Stefanie,Van Liedekerke Ann,Vanheule Geert,Robbrecht Johan,Wirth Claudine,Müller Rüdiger,Kyburz Diego,Sjöwall ChristopherORCID,Kastbom AlfORCID,Ješe RokORCID,Jovancevic Boja,Kiss Emese,Jacques PeggyORCID,Aletaha DanielORCID,Steiner Günter,Verschueren PatrickORCID,Bossuyt XavierORCID

Abstract

IntroductionCommercial assays measuring antibodies to citrullinated protein/peptide (ACPA) show poor quantitative agreement. The diagnostic industry has never adopted the International Union of Immunological Societies-Centers for Disease Control and Prevention (IUIS-CDC) ACPA reference standard. Recently, the National Institute for Biological Standards and Control (NIBSC) prepared a new candidate ACPA standard (18/204). We evaluated both reference materials using different commercially available ACPA assays.Materials and methodsThis is an international study in which the NIBSC candidate ACPA standard and the IUIS-CDC ACPA reference material were analysed together with 398 diagnostic samples from individuals with rheumatoid arthritis (RA) and in 1073 individuals who did not have RA using nine commercial ACPA assays.ResultsFor both reference materials and samples from individuals with RA and individuals who did not have RA, there were large differences in quantitative ACPA results between assays. For most assays, values for the IUIS-CDC standard were lower than values for NIBSC 18/204 and the IUIS-CDC/NIBSC ratio was comparable for several, but not all assays. When NIBSC 18/204 was used as a calibrator, an improvement in alignment of ACPA results across several of the evaluated assays was obtained. Moreover, NIBSC 18/204 could align clinical interpretation for some but not all assays.ConclusionAdoption of an international standard for ACPA determination is highly desirable. The candidate NIBSC 18/204 standard improved the standardisation and alignment of most ACPA assays and might therefore be recommended to be used as reference in commercial assays.

Funder

Roche Diagnostics

Immunodiagnostic Systems Holdings

Siemens Healthineers

Abbott Laboratories

Euroimmun

Svar Life Science

Orgentec

Thermo Fisher Scientific

Bio-Rad Laboratories

Publisher

BMJ

Subject

General Biochemistry, Genetics and Molecular Biology,Immunology,Immunology and Allergy,Rheumatology

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3