Technical and Diagnostic Performance of 6 Assays for the Measurement of Citrullinated Protein/Peptide Antibodies in the Diagnosis of Rheumatoid Arthritis

Author:

Coenen Dries1,Verschueren Patrick2,Westhovens René2,Bossuyt Xavier1

Affiliation:

1. Departments of Laboratory Medicine & Immunology and Rheumatology

2. University Hospital Leuven, Belgium

Abstract

Abstract Background: Several anticitrullinated protein/peptide antibodies (ACPA) assays have been reported to be of diagnostic value for rheumatoid arthritis (RA). We evaluated the technical performance and diagnostic accuracy of 6 ELISAs for the detection of antibodies to citrullinated protein/peptide antigens. Methods: ACPA were determined in 298 serum samples using 6 commercially available ACPA assays. One hundred two samples were from RA patients, including patients with early and established RA, and 196 were from controls, including patients with psoriatic arthritis, connective tissue diseases, organ-specific autoimmune diseases, and a group of consecutive patients for whom a rheumatologist ordered anticyclic citrullinated peptide (CCP) antibodies. The ELISA reagent sets under study were Citrullinated Protein Antibodies (Genesis), Anti-MCV (Orgentec), Immunoscan RA (Euro-Diagnostica), Anti-CCP IgG ELISA (Euroimmun), EliA™ CCP (Phadia), and Quanta Lite™ CCP3 IgG ELISA (Inova). Technical performance (imprecision, linearity, correlation, and agreement) and diagnostic accuracy (sensitivity and specificity) were compared. Results: Variable technical performance was noted among the different ACPA assays, with some assays displaying poor reproducibility and bad linearity. ACPA results were well correlated among assays with the same antigen specificity, but the numerical values reported for each assay differed widely. Using cutoff values proposed by the manufacturer, diagnostic sensitivities ranged between 69.6% and 77.5% and specificities between 87.8% and 96.4%. The areas under the ROC curves were comparable among the different assays. Conclusions: Overall diagnostic performance of ACPA assays is comparable among the different assays, but standardization is needed. For some assays, analytical characteristics could be improved.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3