The uncertainty of estimation of doses to the bone marrow from <sup>89,90</sup>Sr due to the variability of the chemical composition and bone density

Author:

Shishkina E. A.1ORCID,Sharagin P. A.2ORCID,Tolstykh E. A.2ORCID

Affiliation:

1. Urals Research Center for Radiation Medicine, Federal Medical Biological Agency; Chelyabinsk State University

2. Urals Research Center for Radiation Medicine, Federal Medical Biological Agency

Abstract

Dosimetric modeling of radiation transport in skeletal bone tissues using computational phantoms provides the doses of internal exposure to active marrow. Computational phantoms of ICRP are created for reference people with anatomical and physiological characteristics typical of an average individual. The doses calculated with such phantoms will correspond to certain population-average values. Individual variability will introduce a stochastic component of uncertainty into the dose estimation. The objective of this study is to assess the influence of variability of chemical composition and bone density on the results of dosimetric modeling. The phantoms are represented by simple geometry figures filled with trabecular structures and bone marrow and covered with a cortical layer. Radiation transport was simulated using the Monte Carlo method. The dose factors to convert the radionuclide activity concentration to absorbed dose rates in active marrow were calculated assuming uniform radionuclide distribution in the volume of the trabecular and cortical bone. As a result of the numerical experiments, it has been shown that variations in chemical composition do not introduce an error of more than ± 4% into dosimetric modeling. The effect of bone density on active marrow dose formation depends on the size of a phantom. For computational phantoms with linear dimensions exceeding two electron free path lengths (~ 0.44 cm), variability of bone density within ± 3% leads to a similar relative uncertainty of the dose conversion factor. However, for smaller phantoms, bone density variability leads to uncertainties of 6% or 13% for a source deposited in the trabecular or cortical bone, respectively. The results obtained will be used to assess the uncertainty of bone marrow dosimetry, taking into account the uncertainty of all parameters including the variability of morphometric characteristics of bones, the variability of the active marrow distribution in skeletal sites, as well as the uncertainties introduced by model approximations.

Publisher

SPRI of Radiation Hygiene Prof. PV Ramzaev

Subject

Radiology, Nuclear Medicine and imaging

Reference29 articles.

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3