Abstract
Abstract
Background
Persistent organic pollutants (POPs) such as dioxins, dioxin-like chemicals and non-dioxin-like PCBs causing adverse effects to human health bio-accumulate through the food web due to their affinity for adipose tissues. Foods of animal origin are therefore the main contributors to human dietary exposure. The European Union’s (EU) food safety policy requires checking of a wide range of samples for compliance with legal limits on a regular basis. Several methods of varying efficiency are applied by official control laboratories for extraction of the different classes of lipids and associated POPs, bound to animal tissue and animal products in varying degrees, sometimes leading to discrepancies especially in fresh weight based analytical results.
Results
Starting from Smedes’ lipid extraction from marine tissue, we optimized the extraction efficiency for both lipids and lipophilic pollutants, abandoning the time-consuming centrifugation step. The resulting modified Smedes extraction (MSE) method was validated based on multiple analyses of a large number of real-world samples, matrix calibration and performance assessment in proficiency testing utilizing both instrumental and bioanalytical methodologies. Intermediate precision in 12 different foods was below 3% in chicken eggs, egg powder, animal fat, fish, fish oil, poultry, whole milk, milk fat and milk powder, and below 5% in bovine meat, liver, and infant food. In comparison to Twisselmann hot extraction, results presented here show an increased efficiency of MSE by + 25% for bovine liver, + 14% for chicken eggs, + 13% for poultry meat, + 12% for fish, 8% for bovine meat, and 6% for infant food.
Conclusions
For the first time, a fast and reliable routine method is available that enables the analyst to reproducibly extract "total" lipids from any EU-regulated food sample of animal origin within 6 to 8 min. Increased efficiency translates into a considerable increase in both lipid and wet weight-based analytical results measured for associated POPs, reducing the risk of false non-compliant results. Compared to a 4 h Twisselmann extraction, the extraction of 1000 samples using MSE would result in annual savings of about 250 h or 32 working days. Our MSE procedure contributes to the European Commission's objective of harmonizing analytical results across the EU generated according to Commission Regulation (EU) 2017/644.
Funder
National Institute for Environmental Health Sciences
Publisher
Springer Science and Business Media LLC
Reference142 articles.
1. Becker L, Hennecke D, Düring R-A (2011) Assessment of exposure and transfer of Dioxins, dioxin-like PCBs and PCBs – Literature review. Fraunhofer Institute for Molecular Biology and Applied Ecology, and Justus-Liebig-University Giessen.
2. Commission Regulation (EU) 2017/644 of 5 April 2017 laying down methods of sampling and analysis for the control of levels of dioxins, dioxin-like PCBs and non-dioxin-like PCBs in certain foodstuffs and repealing Regulation (EU) No 589/2014, OJ L 92, 06.04.2017, p. 9–34.
3. Fahy E, Cotter D, Sud M (1811) Subramaniam S (2011) Lipid classification, structures and tools. Biochim Biophys Acta 11:637–647
4. Kikas P, Chalikias G, Tziakas D (2018) Cardiovascular implications of sphingomyelin presence in biological membranes. Eur Cardiol 13(1):42–45
5. Martin S, Parton RG (2006) Lipid droplets: a unified view of a dynamic organelle. Nat Rev Mol Cell Biol 7:373–378
Cited by
17 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献