Timing limits of ultrafast cross-luminescence emission in CsZnCl-based crystals for TOF-CT and TOF-PET

Author:

Herweg Katrin,Rutstrom Daniel,Nadig Vanessa,Stand Luis,Melcher Charles L.,Zhuravleva Mariya,Schulz Volkmar,Gundacker StefanORCID

Abstract

Abstract Background Good timing resolution in medical imaging applications such as TOF-CT or TOF-PET can boost image quality or patient comfort significantly by reducing the influence of background noise. However, the timing resolution of state-of-the-art detectors in CT and PET are limited by their light emission process. Core-valence cross-luminescence is an alternative, but well-known compounds (e.g. BaF2) pose several problems for medical imaging applications, such as their emission wavelength in the deep UV. CsZnCl-based materials show promise to solve this issue, as they provide fast decay times of 1–2 ns and an emission wavelength around 300 nm. Results In this work, we investigated two CsZnCl-compounds: Cs2ZnCl4 and Cs3ZnCl5. We validated the previously published decay times on a time-correlated single-photon counting setup with 1.786 ± 0.016 ns for Cs2ZnCl4 and 1.034 ± 0.013 ns for Cs3ZnCl5. The setup’s high resolution enabled the discovery of an additional prompt emission component with a significant abundance of 98 ± 18 (Cs2ZnCl4) and 86 ± 14 (Cs3ZnCl5) photons/MeV energy deposit. In a PET coincidence experiment, we measured the best coincidence time resolution (CTR) of 62 ps (FWHM) for Cs2ZnCL4 coupled to FBK VUV SiPMs with silicon oil. To assess the CTR for lower energies, we filtered the energy along the Compton continuum and found a deteriorated CTR that seems to be mainly influenced by photon statistics. Furthermore, this study gave us a rough estimate of e.g. 150 ps (FWHM) CTR at 100 keV energy for Cs2ZnCL4. From measurements with high activity of 14 MBq to check for pile-up effects we assume that Cs2ZnCl4 is better suited for high-rate time-of-flight applications than lutetium-based oxides. Simulations demonstrated that the stopping power of Cs2ZnCl4 is lower than for LSO:Ce,Ca, meaning that a high amount of material would be needed for TOF-PET applications. However, the stopping power seems acceptable for applications in TOF-CT. Conclusions The fast decay time, state-of-the-art CTR in benchtop experiments and high-rate suitability make CsZnCl materials a promising candidate for time-of-flight experiments. We consider especially TOF-CT a suitable application due to its relatively low X-ray energies (~ 100 keV) and the thusly acceptable stopping power of Cs2ZnCl4. Currently, further exploration of the prompt emission and its creation mechanism is planned, as well as investigating the light transport of Cs2ZnCl4 in longer crystals.

Funder

Nuclear Science and Security Consortium

Universitätsklinikum RWTH Aachen

Publisher

Springer Science and Business Media LLC

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3