Kidney dosimetry in 777 patients during 177Lu-DOTATATE therapy: aspects on extrapolations and measurement time points

Author:

Sandström MattiasORCID,Freedman Nanette,Fröss-Baron Katarzyna,Kahn Tanweera,Sundin Anders

Abstract

Abstract Purpose Fractionated peptide receptor radionuclide therapy (PRRT) with 177Lu-DOTATATE is increasingly applied as an effective treatment for patients with disseminated neuroendocrine tumors. In parallel to dose planning before external beam radiation therapy, dosimetry is also needed to optimize PRRT to the individual patient. Accordingly, absorbed doses to organs at risk need to be calculated during PRRT, based on serial measurements of radioactivity distribution utilizing SPECT/CT. The dosimetry should be based on as few measurements as possible, while still retaining reliable results. The main aim of the present work was to calculate the fractional contribution of the extrapolations of the curve fits for the absorbed dose calculations to the kidneys. The secondary aim was to study agreement between absorbed dose (AD) and the effective half-life (teff) for the kidneys, estimated by means of measurements at one or two time points, in comparison to our current method employing three time points. Methods In 777 patients with disseminated neuroendocrine tumors undergoing PRRT, SPECT/CT over the abdomen was acquired at 1, 4, and 7 days after 177Lu-DOTATATE infusion. The absorbed dose to the kidneys was calculated from SPECT/CT radioactivity distribution data, and the teff and fractional contributions of the extrapolations were estimated, utilizing data from one, two, and three time points, respectively. Results The fractional contributions from extrapolations before day 1 measurement and after day 7 measurement were approximately 26% and 11%, respectively. The mean differences in absorbed dose, based on one, two, and three time points were small, but with high method dependence for individual patients. The differences in estimated teff were small when it was based on measurements at days 1 and 7, but high for days 1 and 4 time points. Conclusion When assessing simplifications of methods for calculation of the absorbed dose to the kidneys, it was of the uttermost importance to incorporate the fractional contribution for the extrapolations included in the reference method. Measurements at an early and a late time point were found most important. An intermediate measurement contributes with an idea of the goodness of the fit.

Funder

Akademiska Sjukhuset

Uppsala Universitet

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Biomedical Engineering,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3