Optimization of PET protocol and interrater reliability of 18F-PSMA-11 imaging of prostate cancer

Author:

Piron SarahORCID,De Man Kathia,Schelfhout Vanessa,Van Laeken Nick,Kersemans Ken,Achten Eric,De Vos Filip,Ost Piet

Abstract

Abstract Background Several scan parameters for PET imaging with 18F-PSMA-11 such as dosage, acquisition time and scan duration were evaluated to determine the most appropriate scan protocol, as well as the effect of furosemide administration on lesion visualization. Forty-four patients were randomly assigned to a dosage group (2.0 ± 0.2 or 4.0 ± 0.4 MBq/kg 18F-PSMA-11). All patients received a full-body PET/CT 1 h and 3 h after radiotracer injection with a scan duration of 3 min/bed position. For comparison of the scan duration, images were reconstructed for 1.5 and 3 min/bed position. Patients were intravenously administered 0.5 mg/kg furosemide with a maximum dose of 40 mg. To evaluate the furosemide effect, 22 additional patients were recruited and received one full-body PET/CT 1 h after administration of 2.0 ± 0.2 MBq/kg 18F-PSMA-11 with a scan duration of 3 min/bed position. To this group, no furosemide was administered. Images were scored on image quality using a 7-point scale and each suspicious lesion was described. To assess interrater reliability, two nuclear physicians scored all scans independently and described all observed suspicious lesions. Results The 4 MBq/kg group received for all reconstructed images (60 min p.i., 1.5 and 3 min/bed position and 180 min p.i., 1.5 and 3 min/bed position) the highest median image quality score compared to the 2 MBq/kg group (p values < 0.01). When comparing all reconstructed images, the highest image quality score was given to images at 60 min p.i., 3 min/bed position for both dosage groups (score 5 and 6 for 2 and 4 MBq/kg, respectively). The addition of furosemide administration decreased the interference score with one point (p = 0.01106) and facilitated the evaluation of lesions in proximity to the ureters. The interrater reliability for the comparison of each lesion separately after more than 40 18F-PSMA-11 scan readings showed an increasing κ value from 0.78 (95% CI, 0.65–0.92) to 0.94 (95% CI, 0.87–1). Conclusion Although the results indicate an administered activity of 4.0 ± 0.4 MBq/kg, preference will be given to 2.0 ± 0.2 MBq/kg due to the small difference in absolute score (max 1 point) and the ALARA principle. For evaluation of lesions in proximity to the ureters, the co-administration of a diuretic can be useful. The increase of the κ value from 0.78 to 0.94 suggests a learning curve in the interpretation of 18F-PSMA-11 images. Trial registration Clinicaltrials.gov, NCT03573011. Retrospectively registered 28 June 2018

Funder

Fonds Wetenschappelijk Onderzoek

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3