Author:
Romanò Carlo Luca,D’Anchise Roberto,Calamita Marco,Manzi Giovanni,Romanò Delia,Sansone Valerio
Abstract
Abstract
Background
Diagnosis of peri-prosthetic infection remains challenging, often requiring a combination of different tests.
Methods
In this prospective, case–control study, the diagnostic accuracy of telethermography was evaluated in a group of seventy patients who had had a total knee replacement and were undergoing a reoperation because of infection or another implant-related problem, after a minimum of one year from implant.
Results
An average differential temperature of the affected versus not affected knee of 1.9°C was observed in infected prosthesis, compared to 0.3°C in aseptic failures. Considering a normal reference value equal or less than 1.0°C, telethermography showed an accuracy, sensitivity, specificity, positive and negative predictive value of, respectively: 0.90, 0.89, 0.91, 0.91, 0.88.
Conclusions
Digital telethermography is a reliable option for diagnosing peri-prosthetic knee infection.
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,Rheumatology
Cited by
19 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献