Improvement of vertebral body fracture reduction utilizing a posterior reduction tool: a single-center experience

Author:

Hoffmann Martin F.,Kuhlmann Kristina,Schildhauer Thomas A.,Wenning Katharina E.

Abstract

Abstract Background Extensive research regarding instabilities and prevention of kyphotic malalignment in the thoracolumbar spine exists. Keystones of this treatment are posterior instrumentation and anterior vertebral height restoration. Anterior column reduction via a single-stage procedure seems to be advantageous regarding complication, blood loss, and OR-time. Mechanical elevation of the anterior cortex of the vertebra may prevent the necessity of additional anterior stabilization or vertebral body replacement. The purpose of this study was to examine (1) if increased bony reduction in the anterior vertebral cortex could be achieved by utilization of an additional reduction tool, (2) if postoperative loss of vertebral height could be reduced, and (3) if anterior column reduction is related to clinical outcome. Methods From one level I trauma center, 173 patients underwent posterior stabilization for fractures of the thoracolumbar region between 2015 and 2020. Reduction in the vertebral body was performed via intraoperative lordotic positioning or by utilization of an additional reduction tool (Nforce, Medtronic). The reduction tool was mounted onto the pedicle screws and removed after tightening of the locking screws. To assess bony reduction, the sagittal index (SI) and vertebral kyphosis angle (VKA) were measured on X-rays and CT images at different time points ((1) preoperative, (2) postoperative, (3) ≥ 3 months postoperative). Clinical outcome was assessed utilizing the Ostwestry Disability Index (ODI). Results Bisegmental stabilization of AO/OTA type A3/A4 vertebral fractures was performed in 77 patients. Thereof, reduction was performed in 44 patients (females 34%) via intraoperative positioning alone (control group), whereas 33 patients (females 33%) underwent additional reduction utilizing a mechanical reduction tool (instrumentation group). Mean age was 41 ± 13 years in the instrumentation group (IG) and 52 ± 12 years in the control group (CG) (p < 0.001). No differences in terms of gender and comorbidities were found between the two groups. Preoperatively, the sagittal index (SI) was 0.69 in IG compared to 0.74 in CG (p = 0.039), resulting in a vertebral kyphosis angle (VKA) of 15.0° vs. 11.7° (p = 0.004). Intraoperatively, a significantly greater correction of the kyphotic deformity was achieved in the IG (p < 0.001), resulting in a compensation of the initially more severe kyphotic malalignment. The SI was corrected by 0.20–0.88 postoperatively, resulting in an improvement of the VKA by 8.7°–6.3°. In the CG, the SI could be corrected by 0.12–0.86 and the VKA by 5.1°–6.6°. The amount of correction was influenced by the initial deformity (p < 0.001). Postoperatively, both groups showed a loss of correction, resulting in a gain of 0.08 for the SI and 4.1° in IG and 0.03 and 2.0°, respectively. The best results were observed in younger patients with initially severe kyphotic deformity. Considering various influencing factors, clinical outcome determined by the ODI showed no significant differences between both groups. Conclusion Utilization of the investigated reduction tool during posterior stabilization of vertebral body fractures in a suitable collective of young patients with good bone quality and severe fracture deformity may lead to better reduction in the ventral column of the fractured vertebral body and angle correction. Therefore, additional anterior stabilization or vertebral body replacement may be prevented.

Funder

Universitätsklinikum der Ruhr-Universität Bochum

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3