Arthroscopic fixation of humeral greater tuberosity fracture using a W-shaped suture

Author:

Lin Xiaocong,Huang Xiuxi,Fang Kaibin,Dai Zhangsheng

Abstract

Abstract Background Patients with greater tuberosity fractures of the humerus often require surgery. Therefore, there is a need to find a minimally invasive and effective surgical procedure with great patient outcomes. Aim To evaluate the clinical outcomes of the W-shaped suture technique under shoulder arthroscopy in the treatment of greater tuberosity fractures of the humerus. Methods In this retrospective study, a total of 17 patients were included. The fractures were closed, and there was no neurovascular injury. These patients underwent arthroscopically assisted reduction and internal fixation of the greater tuberosity fractures. Fixation was performed using sighting nails combined with a W-shaped suture. The imaging data of the patients were collected, and the ASES score, Constant-Murley score, and VAS score were used to evaluate the patient’s outcome. At the last follow-up (at least 1 year), the range of motion in the affected shoulder was compared with that of the contralateral side. Results The operation was successful in all the patients. The average follow-up time was 13 months. There were no reported complications such as fracture displacement, nonunion, and internal fixation failure during the follow-up period. Post-operative X-ray examinations revealed good function recovery, with a healing time of between 10 and 12 weeks, and an average healing time of 11.5 weeks. Following the operation, patients reported reduced shoulder joint pain that no longer influenced their activity or caused discomfort in their daily life. The patient’s VAS score ranged from 0 to 3, with an average of 0.52 ± 0.73, while at the last follow-up, the Constant-Murley score ranged from 83 to 97, with an average of 92.33 ± 7.55. The ASES score ranged from 81 to 98, with an average of 93.15 ± 6.93. At the last follow-up, there was no significant difference in the overall range of motion with the unaffected limb. Conclusion This study demonstrates that the W-shaped suture can be used to effectively fix the fractures of the greater tuberosity of the humerus, by increasing the fixed area to promote healing.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3