Intraoperative 3D imaging with cone-beam computed tomography leads to revision of pedicle screws in dorsal instrumentation: a retrospective analysis

Author:

Zimmermann Felix,Kohl Katharina,Privalov Maxim,Franke Jochen,Vetter Sven Y.ORCID

Abstract

Abstract Background Correct positioning of pedicle screws can be challenging. Intraoperative imaging may be helpful. The purpose of this study was to evaluate the use of intraoperative 3D imaging with a cone-beam CT. The hypotheses were that intraoperative 3D imaging (1) will lead to an intraoperative revision of pedicle screws and (2) may diminish the rate of perforated screws on postoperative imaging. Methods Totally, 351 patients (age 60.9 ± 20.3 a (15–96); m/f 203/148) underwent dorsal instrumentation with intraoperative 3D imaging with 2215 pedicle screws at a trauma center level one. This study first evaluates intraoperative imaging. After this, 501 screws in 73 patients (age 62.5 ± 19.7 a; m/f 47/26) of this collective were included in the study group (SG) and their postoperative computed tomography was evaluated with regard to screw position. Then, 500 screws in 82 patients (age 64.8 ± 14.4 a; m/f 51/31) as control group (CG), who received the screws with conventional 2D fluoroscopy but without 3D imaging, were evaluated with regard to screw position. Results During the placement of the 2215 pedicle screws, 158 (7.0%) intraoperative revisions occurred as a result of 3D imaging. Postoperative computed tomography of the SG showed 445 (88.8%) screws without relevant perforation (type A + B), of which 410 (81.8%) could be classified as type A and 35 (7.0%) could be classified as type B. Fifty-six (11.2%) screws in SG showed relevant perforation (type C–E). In contrast, 384 (76.8%) screws in the CG were without relevant perforation (type A + B), of which 282 (56.4%) could be classified as type A and 102 (20.4%) as type B. One hundred and sixteen (23.2%) screws in the CG showed relevant perforation (type C–E). Conclusion This study shows that correct placement of pedicle screws in spine surgery with conventional 2D fluoroscopy is challenging. Misplacement of screws cannot always be prevented. Intraoperative 3D imaging with a CBCT can be helpful to detect and revise misplaced pedicle screws intraoperatively. The use of intraoperative 3D imaging will probably minimize the number of revision procedures due to perforating pedicle screws.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3