Abstract
Abstract
Background
No available meta-analysis has been published that systematically assessed spinal fixation mechanical failure after tumor resection based on largely pooled data. This systematic review and meta-analysis aimed to investigate the spinal fixation failure rate and potential risk factors for hardware failure.
Methods
Electronic articles published between January 1, 1979, and January 30, 2021, were searched and critically evaluated. The authors independently reviewed the abstracts and extracted data on the spinal fixation failure rate and potential risk factors.
Results
Thirty-eight studies were finally included in the meta-analysis. The pooled spinal fixation mechanical failure rate was 10%. The significant risk factors for hardware failure included tumor level and cage subsidence. Radiotherapy was a potential risk factor.
Conclusion
The spinal fixation mechanical failure rate was 10%. Spinal fixation failure is mainly associated with tumor level, cage subsidence and radiotherapy. Durable reconstruction is needed for patients with these risk factors.
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,Surgery
Reference38 articles.
1. Bilsky MH, Boakye M, Collignon F, Kraus D, Boland P. Operative management of metastatic and malignant primary subaxial cervical tumors. J Neurosurg Spine. 2005;2:256–64.
2. Villavicencio AT, Oskouian RJ, Roberson C, Stokes J, Park J, Shaffrey CI, Johnson JP. Thoracolumbar vertebral reconstruction after surgery for metastatic spinal tumors: long-term outcomes. Neurosurg Focus. 2005;19:E8.
3. Li ZH, Wei F, Liu ZJ, Liu XG, Jiang L, Yu M, Xu NF, Wu FL, Dang L, Zhou H, Li ZH. Risk factors for instrumentation failure after total en bloc spondylectomy of thoracic and lumbar spine tumors using titanium mesh cage for anterior reconstruction. World Neurosurg. 2020;135:66.
4. Park SJ, Lee CS, Chang BS, Kim YH, Kim H, Kim SI, Chang SY. Rod fracture and related factors after total en bloc spondylectomy. Spine J. 2019;19:1613–9.
5. Yoshioka K, Murakami H, Demura S, Kato S, Yokogawa N, Kawahara N, Tomita K, Tsuchiya H. Risk factors of instrumentation failure after multilevel total en bloc spondylectomy. Spine Surg Rel Res. 2017;1:31–9.
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献