Advantages of patient-specific cutting guides with disposable instrumentation in total knee arthroplasty: a case control study

Author:

Moerenhout KevinORCID,Allami Behrang,Gkagkalis Georgios,Guyen Olivier,Jolles Brigitte M.

Abstract

Abstract Background Total knee arthroplasty (TKA) is most frequently planned using conventional two-dimensional weight-bearing lower limb radiographs and is performed with conventional femoral and tibial cutting guides. Questions have been raised about the accuracy of conventional TKA instrumentation and planning for an anatomically standard or complex joint. Use of computed tomography (CT)-based three-dimensional (3D) templating and patient-specific cutting guides printed in 3D has shown improved postoperative lower limb alignment parameters. This case-control study compared costs and operative times of using CT-based, patient-specific, single-use instruments versus conventional metal instruments for TKA. Methods In this case-control, retrospective chart review, all TKAs were performed by one senior surgeon, using the F.I.R.S.T. posterior-stabilised knee prosthesis (Symbios, CH), with a similar protocol and identical operating room setup. Group A included 51 TKAs performed with patient-specific cutting guides and conventional metal instruments. Group B included 49 TKAs performed with patient-specific cutting guides and patient-specific, single-use instrumentation. Operation duration, number of instrumentation trays and sterilisation costs were evaluated. Results The groups were similar for age, body mass index, hip-knee-ankle angle and operation duration. The mean number of instrumentation trays was 8.0 ± 0.8 for group A (controls) and 5.1 ± 0.9 for group B (p<0.001). The mean sterilisation costs were 380 ± 47 Swiss Francs (CHF) for group A and 243 ± 55 CHF for group B (p<0.001), for a mean cost reduction of 130.50 CHF per intervention in group B. The time interval between two consecutive surgeries was 24 min for group A and 18 min for group B. There were no adverse events or complications, instrument-related or otherwise. Conclusion Compared to conventional instrumentation, use of patient-specific, single-use instruments for TKA reduced the number of instrumentation trays by more than one-third and saved 36% in sterilisation costs. If fabrication costs of single-use instruments are included by the company, the total cost is significantly diminished. There was no operative time advantage for single-use instrumentation.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3