Assessing real-world gait with digital technology? Validation, insights and recommendations from the Mobilise-D consortium

Author:

Micó-Amigo M. Encarna,Bonci Tecla,Paraschiv-Ionescu Anisoara,Ullrich Martin,Kirk Cameron,Soltani Abolfazl,Küderle Arne,Gazit Eran,Salis Francesca,Alcock Lisa,Aminian Kamiar,Becker Clemens,Bertuletti Stefano,Brown Philip,Buckley Ellen,Cantu Alma,Carsin Anne-Elie,Caruso Marco,Caulfield Brian,Cereatti Andrea,Chiari Lorenzo,D’Ascanio Ilaria,Eskofier Bjoern,Fernstad Sara,Froehlich Marcel,Garcia-Aymerich Judith,Hansen Clint,Hausdorff Jeffrey M.,Hiden Hugo,Hume Emily,Keogh Alison,Kluge Felix,Koch Sarah,Maetzler Walter,Megaritis Dimitrios,Mueller Arne,Niessen Martijn,Palmerini Luca,Schwickert Lars,Scott Kirsty,Sharrack Basil,Sillén Henrik,Singleton David,Vereijken Beatrix,Vogiatzis Ioannis,Yarnall Alison J.,Rochester Lynn,Mazzà Claudia,Del Din Silvia,

Abstract

Abstract Background Although digital mobility outcomes (DMOs) can be readily calculated from real-world data collected with wearable devices and ad-hoc algorithms, technical validation is still required. The aim of this paper is to comparatively assess and validate DMOs estimated using real-world gait data from six different cohorts, focusing on gait sequence detection, foot initial contact detection (ICD), cadence (CAD) and stride length (SL) estimates. Methods Twenty healthy older adults, 20 people with Parkinson’s disease, 20 with multiple sclerosis, 19 with proximal femoral fracture, 17 with chronic obstructive pulmonary disease and 12 with congestive heart failure were monitored for 2.5 h in the real-world, using a single wearable device worn on the lower back. A reference system combining inertial modules with distance sensors and pressure insoles was used for comparison of DMOs from the single wearable device. We assessed and validated three algorithms for gait sequence detection, four for ICD, three for CAD and four for SL by concurrently comparing their performances (e.g., accuracy, specificity, sensitivity, absolute and relative errors). Additionally, the effects of walking bout (WB) speed and duration on algorithm performance were investigated. Results We identified two cohort-specific top performing algorithms for gait sequence detection and CAD, and a single best for ICD and SL. Best gait sequence detection algorithms showed good performances (sensitivity > 0.73, positive predictive values > 0.75, specificity > 0.95, accuracy > 0.94). ICD and CAD algorithms presented excellent results, with sensitivity > 0.79, positive predictive values > 0.89 and relative errors < 11% for ICD and < 8.5% for CAD. The best identified SL algorithm showed lower performances than other DMOs (absolute error < 0.21 m). Lower performances across all DMOs were found for the cohort with most severe gait impairments (proximal femoral fracture). Algorithms’ performances were lower for short walking bouts; slower gait speeds (< 0.5 m/s) resulted in reduced performance of the CAD and SL algorithms. Conclusions Overall, the identified algorithms enabled a robust estimation of key DMOs. Our findings showed that the choice of algorithm for estimation of gait sequence detection and CAD should be cohort-specific (e.g., slow walkers and with gait impairments). Short walking bout length and slow walking speed worsened algorithms’ performances. Trial registration ISRCTN – 12246987.

Publisher

Springer Science and Business Media LLC

Subject

Health Informatics,Rehabilitation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3