Abstract
Abstract
Background
Biofilm formation is one of the main reasons for persistent bacterial infections. Recently, pH-sensitive copolymers have fascinated incredible attention to tackle biofilm-related infections. However, the proper incorporation of pH-sensitive segments in the polymer chains, which could significantly affect the biofilms targeting ability, has not been particularly investigated. Herein, we synthesized three types of pH-sensitive copolymers based on poly (β-amino ester) (PAE), poly (lactic-co-glycolic acid) (PLA) and polyethylene glycol (PEG), PAE-PLA-mPEG (A-L-E), PLA-PAE-mPEG (L-A-E) and PLA-PEG-PAE (L-E-A) to address this issue.
Results
The three copolymers could self-assemble into micelles (MA-L-E, ML-A-E and ML-E-A) in aqueous medium. Compared with MA-L-E and ML-A-E, placing the PAE at the distal PEG end of PLA-PEG to yield PLA-PEG-PAE (ML-E-A) was characterized with proper triggering pH, fully biofilm penetration, and high cell membrane binding affinity. Further loaded with Triclosan (TCS), ML-E-A/TCS could efficiently kill the bacteria either in planktonic or biofilm mode. We reasoned that PAE segments would be preferentially placed near the surface and distant from the hydrophobic PLA segments. This would increase the magnitude of surface charge-switching capability, as the cationic PAE+ would easily disassociate from the inner core without conquering the additional hydrophobic force arising from covalent linkage with PLA segments, and rapidly rise to the outermost layer of the micellar surface due to the relative hydrophilicity. This was significant in that it could enable the micelles immediately change its surface charge where localized acidity occurred, and efficiently bind themselves to the bacterial surface where they became hydrolyzed by bacterial lipases to stimulate release of encapsulated TCS even a relatively short residence time to prevent rapid wash-out. In vivo therapeutic performance of ML-E-A/TCS was evaluated on a classical biofilm infection model, implant-related biofilm infection. The result suggested that ML-E-A/TCS was effective for the treatment of implant-related biofilm infection, which was proved by the efficient clearance of biofilm-contaminated catheters and the recovery of surrounding infected tissues.
Conclusions
In summary, elaboration on the architecture of pH-sensitive copolymers was the first step to target biofilm. The ML-E-A structure may represent an interesting future direction in the treatment of biofilm-relevant infections associated with acidity.
Graphic abstract
Funder
Taishan Scholar Project of Shandong Province
Key Program of Natural Science Foundation of Shandong Province
Publisher
Springer Science and Business Media LLC
Subject
Pharmaceutical Science,Applied Microbiology and Biotechnology,Biomedical Engineering,Molecular Medicine,Medicine (miscellaneous),Bioengineering
Cited by
19 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献