Impact of ferumoxytol vs gadolinium on 4D flow cardiovascular magnetic resonance measurements in small children with congenital heart disease

Author:

Kollar Sarah E.ORCID,Udine Michelle L.,Mandell Jason G.,Cross Russell R.,Loke Yue-Hin,Olivieri Laura J.

Abstract

Abstract Background Cardiovascular magnetic resonance (CMR) allows for time-resolved three-dimensional phase-contrast (4D Flow) analysis of congenital heart disease (CHD). Higher spatial resolution in small infants requires thinner slices, which can degrade the signal. Particularly in infants, the choice of contrast agent (ferumoxytol vs. gadolinium) may influence 4D Flow CMR accuracy. Thus, we investigated the accuracy of 4D Flow CMR measurements compared to gold standard 2D flow phase contrast (PC) measurements in ferumoxytol vs. gadolinium-enhanced CMR of small CHD patients with shunt lesions. Methods This was a retrospective study consisting of CMR studies from complex CHD patients less than 20 kg who had ferumoxytol or gadolinium-enhanced 4D Flow and standard two-dimensional phase contrast (2D-PC) flow collected. 4D Flow clinical software (Arterys) was used to measure flow in great vessels, systemic veins, and pulmonary veins. 4D Flow accuracy was defined as percent difference or correlation against conventional measurements (2D-PC) from the same vessels. Subgroup analysis was performed on two-ventricular vs single-ventricular CHD, arterial vs venous flow, as well as low flows (defined as < 1.5 L/min) in 1V CHD. Results Twenty-one ferumoxytol-enhanced and 23 gadolinium-enhanced CMR studies were included, with no difference in age (2.1 ± 1.6 vs. 2.3 ± 1.9 years, p = 0.70), patient body surface area (0.50 ± 0.2 vs. 0.52 ± 0.2 m2, p = 0.67), or vessel diameter (11.4 ± 5.2 vs. 12.4 ± 5.6 mm, p = 0.22). Ten CMR studies with single ventricular CHD were included. Overall, ferumoxytol-enhanced 4D flow CMR measurements demonstrated less percent difference to 2D-PC when compared to gadolinium-enhanced 4D Flow CMR studies. In subgroup analyses of arterial vs. venous flows (high velocity vs. low velocity) and low flow in single ventricle CHD, ferumoxytol-enhanced 4D Flow CMR measurements had stronger correlation to 2D-PC CMR. The contrast-to-noise ratio (CNR) in ferumoxytol-enhanced studies was higher than the CNR in gadolinium-enhanced studies. Conclusions Ferumoxytol-enhanced 4D Flow CMR has improved accuracy when compared to gadolinium 4D Flow CMR, particularly for infants with small vessels in CHD.

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3