Abstract
Abstract
Background
Home blood pressure monitoring (HBPM) is an effective tool in treatment and long-term management of hypertension. HBPM incorporates more data points to help patients and providers with diagnosis and management. The characteristics of HBPM devices matter to patients, but the relative importance of the characteristics in choosing a device remains unclear.
Methods
We used data from a randomized cross-over pilot study with 100 Alaska Native and American Indian (ANAI) people with hypertension to assess the choice of a wrist or arm HBPM device. We use a random utility framework to evaluate the relationship between stated likely use, perceived accuracy, ease of use, comfort, and participant characteristics with choice of device. Additional analyses examined willingness to change to a more accurate device.
Results
Participants ranked the wrist device higher compared to the arm on a 5-point Likert scale for likely use, ease of use, and comfort (0.3, 0.5, 0.8 percentage points, respectively). Most participants (66%) choose the wrist device. Likely use (wrist and arm devices) was related to the probability of choosing the wrist (0.7 and − 1.4 percentage points, respectively). Independent of characteristics, 75% of participants would be willing to use the more accurate device. Ease of use (wrist device) and comfort (arm device) were associated with the probability of changing to a more accurate device (− 1.1 and 0.5 percentage points, respectively).
Conclusion
Usability, including comfort, ease, and likely use, appeared to discount the relative importance of perceived accuracy in the device choice. Our results contribute evidence that ANAI populations value accurate HBPM, but that the devices should also be easy to use and comfortable to facilitate long-term management.
Funder
national institute on minority health and health disparities
Publisher
Springer Science and Business Media LLC
Subject
Cardiology and Cardiovascular Medicine
Reference55 articles.
1. Whelton PK, Carey RM, Aronow WS, Casey DE, Collins KJ, Dennison Himmelfarb C, et al. 2017 ACC/AHA/AAPA/ABC/ACPM/AGS/APhA/ASH/ASPC/NMA/PCNA guideline for the prevention, detection, evaluation, and management of high blood pressure in adults: executive summary. Hypertension. 2018;71:1269–324. https://doi.org/10.1161/HYP.0000000000000066.
2. Physician HC, Unit MM, Hospital N. The use of home blood pressure monitoring. Eur Cardiol Rev. 2015;10(2):95–101.
3. Melville S, Teskey R, Philip S, Simpson JA, Lutchmedial S, Brunt KR. A comparison and calibration of a wrist-worn blood pressure monitor for patient management: assessing the reliability of innovative blood pressure devices. J Med Internet Res. 2018;20(4):e111.
4. Cao X, Song C, Guo L, Yang J, Deng S, Xu Y, et al. Quality control and validation of oscillometric blood pressure measurements taken during an epidemiological investigation. Medicine (United States). 2015;94(37):e1475.
5. Kikuya M, Chonan K, Imai Y, Goto E, Ishii M. Accuracy and reliability of wrist-cuff devices for self-measurement of blood pressure. J Hypertens. 2002;20(4):629–38.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献