Non-invasive quantification of pressure–volume loops in patients with Fontan circulation

Author:

Sjöberg Pia,Liuba Petru,Arheden Håkan,Heiberg Einar,Carlsson Marcus

Abstract

Abstract Background Pressure–volume (PV) loops provide comprehensive information of cardiac function, but commonly implies an invasive procedure under general anesthesia. A novel technique has made it possible to non-invasively estimate PV loops with cardiac magnetic resonance (CMR) and brachial pressure which would enable good volume estimation of often anatomically complex ventricles without the need of anesthesia in most cases. In this study we aimed to compare how hemodynamic parameters derived from PV loops in patients with Fontan circulation differ to controls. Methods Patients with Fontan circulation (n = 17, median age 12 years, IQR 6–15) and healthy controls (n = 17, 14 years, IQR 13–22) were examined with CMR. Short axis balanced steady-state free-precession cine images covering the entire heart were acquired. PV loops were derived from left ventricular volumes in all timeframes and brachial blood pressure from cuff sphygmomanometry. Results Fontan patients had lower stroke work, ventricular mechanical efficiency and external power compared to controls. Fontan patients with dominant right ventricle had higher potential energy indexed to body surface area but lower contractility (Ees) compared to controls. Fontan patients had higher arterial elastance (Ea) and Ea/Ees ratio than controls. Contractility showed no correlation with ejection fraction (EF) in Fontan patients irrespective of ventricular morphology. No difference was seen in energy per ejected volume between Fontan patients and controls. Conclusions This non-invasive PV-loop method could be used in future studies to show the potential prognostic value of these measures and if changes in ventricular function over time can be detected earlier by this method compared to changes in ventricular volumes and EF. In contrast to patients with acquired heart failure, Fontan patients had similar energy per ejected volume as controls which suggests similar ventricular oxygen consumption to deliver the same volume in Fontan patients as in controls.

Funder

Region Skåne

Svenska Läkaresällskapet

Knut och Alice Wallenbergs Stiftelse

Lunds Universitet

Skånes universitetssjukhus

Vetenskapsrådet

Hjärt-Lungfonden

Lund University

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3