Abstract
Abstract
Background
To evaluate the prognostic value of peak serum lactate and lactate clearance at several time points in cardiogenic shock treated with temporary mechanical circulatory support (MCS) using veno-arterial extracorporeal membrane oxygenation (VA-ECMO) or Impella CP®.
Methods
Serum lactate and clearance were measured before MCS and at 1 h, 6 h, 12 h, and 24 h post-MCS in 43 patients at four tertiary-care centers in Southern Brazil. Prognostic value was assessed by univariable and multivariable analysis and receiver operating characteristic (ROC) curves for 30-day mortality.
Results
VA-ECMO was the most common MCS modality (58%). Serum lactate levels at all time points and lactate clearance after 6 h were associated with mortality on unadjusted and adjusted analyses. Lactate levels were higher in non-survivors at 6 h, 12 h, and 24 h after MCS. Serum lactate > 1.55 mmol/L at 24 h was the best single prognostic marker of 30-day mortality [area under the ROC curve = 0.81 (0.67–0.94); positive predictive value = 86%). Failure to improve serum lactate after 24 h was associated with 100% mortality.
Conclusions
Serum lactate was an important prognostic biomarker in cardiogenic shock treated with temporary MCS. Serum lactate and lactate clearance at 24 h were the strongest independent predictors of short-term survival.
Funder
Brazilian Ministry of Health - PROADI program
Publisher
Springer Science and Business Media LLC
Subject
Cardiology and Cardiovascular Medicine
Cited by
29 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献