Author:
Woo Seung Hun,Kwak Sang Ho,Jang Hyo Seok,Kim Dong Hee,Seo Jang Hyeon,Lee Sang Hyun
Abstract
Abstract
Background
The axial headless compression screw (AHCS) technique is a widely used method for distal interphalangeal joint (DIPJ) and thumb IPJ arthrodesis. However, it might not be suitable for cases over 10° flexion of fusion angle and extremely small-sized phalanx. Here, the authors describe the nonaxial multiple small screws (NMSS) technique, compare the mechanical strength of the NMSS technique with the AHCS technique, and suggest clinical outcomes of the NMSS technique.
Methods
DIPJ and thumb IPJ arthrodesis models were simulated in the 4th generation composite bone hand. Fixation with three 1.5 mm cortical screws (NMSS) or one HCS (AHCS) was performed in each pair of the phalanx. The bending stiffness and load to failure were tested in 10 pairs of each specimen, and the torsional stiffness and torque to failure were tested in seven pairs of each specimen. Moreover, 15 consecutive clinical DIPJ and thumb IPJ arthrodesis cases were reviewed retrospectively.
Results
The NMSS specimens showed significantly higher bending load to failure, torsional stiffness, and torque to failure than the AHCS specimens. All 15 arthrodesis cases were united without severe complications. The mean fusion angle was 16.3° for the nine cases of the flexed target position.
Conclusions
The NMSS technique showed biomechanical stability comparable to that of the AHCS technique in DIPJ and thumb IPJ arthrodesis. Thus, the NMSS technique could be used as a feasible option in DIPJ and thumb IPJ arthrodesis, especially when a small finger is indicated and a significant flexion angle is required.
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,Rheumatology
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献