Abstract

Abstract Purpose To report the clinical and radiographic results of arthrodesis of relatively small-sized distal interphalangeal joints (DIPJs) using only K-wire fixation. Patients and methods Between January 2000 and December 2018 28 arthrodesis in 21 patients (9 males and 12 females with an average age of 52.1 years) with relatively small-sized DIPJs were performed using only K-wires. Data on patient’s characteristics, such as age, sex, affected finger, and the number and size of the used k-wires were collected from the medical database. The narrowest diameter of the cortex and medulla of the distal phalanx was measured on preoperative plain radiographs. The time to union and the arthrodesis angle was determined using serial X-ray radiography follow-up. Preoperatively and at the latest follow-up examination, pain using the visual analogue scale (VAS) and the quick DASH score was registered. In addition, complications were investigated. Results Average follow-up period was 11.4 months. The small finger was mostly affected (n = 12; 42.9 %). The narrowest diameters of the distal phalanx cortex and the medulla measured on preoperative X-ray images were 2.8 mm (SD 0.5) and 1.2 mm (SD 0.4), respectively. Seven fusions were done with use of 1 K-wire, 20 with 2 (71.4 %), and 1 with 3 K-wires. The most common K-wire sizes were 1.1-inch (24 K-wires = 48 %), and 0.9 inch (21 K-wires = 42 %) The preoperative VAS score and quick DASH score improved from 6.1 (range: 0–9) and 25.8 (range: 2–38) to 0.4 (range: 0–2) and 3.4 (range: 0–10.2), respectively. 25 (89.3 %) out of 28 fingers achieved bony union in an average of 96.1 days (range: 58–114) with three non-union. Conclusion Arthrodesis of small DIPJs with K-wire fixation has a high success rate. Therefore, we suggest K-wire fixation as an acceptable alternative for patients with a small phalanx which may be at risk of mismatch with bigger implants. However, concerns remain in terms of fusion delay with K-wire only fixation.

Publisher

Georg Thieme Verlag KG

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3