A novel bone cement injector augments Chinese osteoporotic lumbar pedicle screw channel: a biomechanical investigation

Author:

Fu Suochao,Zhang Yu,Ai Fuzhi,Wang Jianhua,Wu Zenghui,Ma Xiangyang,Wu Zixiang,Wang Zheng,Lei Wei,Xia Hong

Abstract

Abstract Background The study aimed to (1) create a series of pedicle injectors with different number of holes on the sheath especially for the Chinese elderly patients and (2) further investigate the effects of the injectors on the augmentation of pedicle screw among osteoporotic lumbar pedicle channel. Methods This study used the biomechanical test module of polyurethane (Pacific Research Laboratory Corp, USA) to simulate the mechanical properties of human osteoporotic cancellous bone. The bone cement injectors were invented based on anatomical parameters of lumbar pedicle in Chinese elderly patients. Mechanical test experiments were performed on the bone cement injectors according to the three groups, namely, a local augmentation group, a full-length augmentation group, and a control group. The local augmentation group included three subgroups including 4-hole group, 6-hole group, and 8-hole group. All holes were laterally placed. The full-length augmentation group was a straight-hole injector. The control group was defined that pedicle screws were inserted without any cement augmentation. Six screws were inserted in each group and the maximum insertion torque was recorded. After 24 h of injecting acrylic bone cement, routine X-ray and CT examinations were performed to evaluate the distribution of bone cement. The axial pull-out force of screws was tested with the help of the material testing system 858 (MTS-858) mechanical tester. Results The bone cement injectors were consisted of the sheaths and the steel rods and the sheaths had different number of lateral holes. The control group had the lowest maximum insertion torque as compared with the 4-hole, 6-hole, 8-hole, and straight pore groups (P < 0.01), but the differences between the 4-hole, 6-hole, 8-hole, and straight pore groups were no statistical significance. The control group had the lowest maximum axial pull-out force as compared with the other four groups (P < 0.01). Subgroup analysis showed the 8-hole group (161.35 ± 27.17 N) had the lower maximum axial pull-out force as compared with the 4-hole group (217.29 ± 49.68 N), 6-hole group (228.39 ± 57.83 N), and straight pore group (237.55 ± 35.96 N) (P < 0.01). Bone cement was mainly distributed in 1/3 of the distal end of the screw among the 4-hole group, in the middle 1/3 and distal end of the screw among the 6-hole group, in the proximal 1/3 of the screw among the 8-hole group, and along the long axis of the whole screw body in the straight pore group. It might indicate that the 8-hole and straight-hole groups were more vulnerable to spinal canal cement leakage. After pullout, bone cement was also closely connected with the screw without any looseness or fragmentation. Conclusions The bone cement injectors with different number of holes can be used to augment the pedicle screw channel. The pedicle screw augmented by the 4-hole or 6-hole sheath may have similar effects to the straight pore injector. However, the 8-hole injector may result in relatively lower pull-out strength and the straight pore injector has the risks of cement leakage as well as cement solidarization near the screw head.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3