Calcium phosphate cement promotes the stability of osteoporotic lumbar pedicle screw by enhancer-injecters with different number of holes

Author:

Fu Suochao,Zhang Yu,Wang Renkai,Zou Xiaobao,Ai Fuzhi,Wang Jianhua,Ma Xiangyang,Xia Hong,Lei Wei

Abstract

Abstract Backgrounds This study aimed to compare whether Calcium phosphate cement (CPC) promotes the stability of osteoporotic lumbar pedicle screw by enhancer-injecters with different number of holes. Methods Through a self-designed bone cement injection device, the pedicle screw canal was strengthened with calcium phosphate bone cement, and divided into 4-hole group, 6-hole group, 8-hole group, straight pore group and the control group. The screw was inserted into the mechanical test module, the Maximum insertion torque and Maximum axial pull-out strength were recorded, and the distribution of calcium phosphate bone cement was analyzed by CT and X-ray. The data results were analyzed using SPSS19.0 statistical software package. Results The distribution of bone cement in different reinforcement groups was different and showed regularity. The bone cement in the 4-hole group was roughly located in the head 1/3 of the screw, the 6-hole group was located in the middle 1/3 of the screw, and the 8-hole group was located in the caudal 1/3 of the screw. Compared with the control group, the maximum axial pull-out force of screws in the lateral hole and full screw tunnel reinforcement group was significantly increased. There was no significant difference between the 4-hole, 6-hole and straight pore groups. There was no difference in the screw-in torque between the reinforcement groups, and they all increased significantly compared with the control group, and the difference was statistically significant. After the screw was pulled out, the interface between the bone cement and the polyurethane material was fractured, and a tight package was formed with the screw. Conclusions Enhancer syringes with different hole numbers combined with CPC bone cement injection can significantly increase the maximum screw pull-out force. The 8-hole group has a smaller pull-out force and is relatively prone to leakage of reinforcing material, which lacks safety in use. The local reinforcement of 4-hole and 6-hole sheath can play a similar role to that of total nail tunnel reinforcement.

Funder

Guangzhou Municipal Science and Technology Project

National Natural Science Foundation of China

Publisher

Springer Science and Business Media LLC

Subject

General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3