Effect of intrafraction adaptation on PTV margins for MRI guided online adaptive radiotherapy for rectal cancer

Author:

Kensen Chavelli M.,Janssen Tomas M.,Betgen Anja,Wiersema Lisa,Peters Femke P.,Remeijer Peter,Marijnen Corrie A. M.,van der Heide Uulke A.

Abstract

Abstract Purpose To determine PTV margins for intrafraction motion in MRI-guided online adaptive radiotherapy for rectal cancer and the potential benefit of performing a 2nd adaptation prior to irradiation. Methods Thirty patients with rectal cancer received radiotherapy on a 1.5 T MR-Linac. On T2-weighted images for adaptation (MRIadapt), verification prior to (MRIver) and after irradiation (MRIpost) of 5 treatment fractions per patient, the primary tumor GTV (GTVprim) and mesorectum CTV (CTVmeso) were delineated. The structures on MRIadapt were expanded to corresponding PTVs. We determined the required expansion margins such that on average over 5 fractions, 98% of CTVmeso and 95% of GTVprim on MRIpost was covered in 90% of the patients. Furthermore, we studied the benefit of an additional adaptation, just prior to irradiation, by evaluating the coverage between the structures on MRIver and MRIpost. A threshold to assess the need for a secondary adaptation was determined by considering the overlap between MRIadapt and MRIver. Results PTV margins for intrafraction motion without 2nd adaptation were 6.4 mm in the anterior direction and 4.0 mm in all other directions for CTVmeso and 5.0 mm isotropically for GTVprim. A 2nd adaptation, applied for all fractions where the motion between MRIadapt and MRIver exceeded 1 mm (36% of the fractions) would result in a reduction of the PTVmeso margin to 3.2 mm/2.0 mm. For PTVprim a margin reduction to 3.5 mm is feasible when a 2nd adaptation is performed in fractions where the motion exceeded 4 mm (17% of the fractions). Conclusion We studied the potential benefit of intrafraction motion monitoring and a 2nd adaptation to reduce PTV margins in online adaptive MRIgRT in rectal cancer. Performing 2nd adaptations immediately after online replanning when motion exceeded 1 mm and 4 mm for CTVmeso and GTVprim respectively, could result in a 30–50% margin reduction with limited reduction of dose to the bowel.

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3