Dose tracking assessment for Magnetic Resonance Guided Adaptive Radiotherapy of rectal cancers

Author:

Xin Xin1,Tang Bin2,Wu Fan2,Lang Jinyi2,Li Jie2,Wang Xianliang2,Liu Min2,Zhang Qingxian1,Liao Xiongfei2,Yang Feng1,Orlandini Lucia Clara2

Affiliation:

1. Chengdu University of Technology

2. Sichuan Cancer Hospital and Research Institute, University of Electronic Sciences and Technology of China

Abstract

Abstract

Background Magnetic resonance-guided adaptive radiotherapy (MRgART) at MR-Linac allows for plan optimisation on the MR-based synthetic CT (sCT) images, adjusting the target and organs at risk according to the patient’s daily anatomy. Conversely, conventional linac image-guided radiotherapy (IGRT) involves rigid realignment of regions of interest to the daily anatomy, followed by the delivery of the reference computed tomography (CT) plan. This study aims to evaluate the effectiveness of MRgART versus IGRT for rectal cancer patients undergoing short-course radiotherapy, while also assessing the dose accumulation process to support the findings and determine its usefulness in enhancing treatment accuracy.Methods Nineteen rectal cancer patients treated with a 1.5 Tesla MR-Linac with a prescription dose of 25 Gy (5Gy x 5) and undergoing daily adapted radiotherapy by plan optimization based on online MR-based sCT images, were included in this retrospective study. For each adapted plan (\(\:{\text{T}\text{P}}_{\text{a}\text{d}\text{a}\text{p}}\)), a second plan (\(\:{\text{T}\text{P}}_{\text{I}\text{G}\text{R}\text{T}}\)) was generated by recalculating the reference CT plan on the daily MR-based sCT images after rigid registration with the reference CT images to simulate the IGRT workflow. Dosimetry of \(\:{\text{T}\text{P}}_{\text{a}\text{d}\text{a}\text{p}}\) and\(\:\:{\text{T}\text{P}}_{\text{I}\text{G}\text{R}\text{T}}\)was compared for each fraction. Cumulative doses on the first and last fractions were evaluated for both workflows. The dosimetry per single fraction and the cumulative doses were compared using dose-volume histogram parameters.Results Ninety-five fractions delivered with MRgART were compared to corresponding simulated IGRT fractions. All MRgART fractions fulfilled the target clinical requirements. IGRT treatments did not meet the expected target coverage for 63 out of 94 fractions (67.0%), with 13 fractions showing a V95 median point percentage decrease of 2.78% (range, 1.65%-4.16%), and 55 fractions exceeding the V107% threshold with a median value of 15.4 cc (range, 6.0-43.8 cc). For the bladder, the median \(\:{\text{D}}_{15\text{c}\text{c}}\) values were 18.18 Gy for the adaptive fractions and 19.60 Gy for the IGRT fractions. Similarly the median \(\:{\text{D}}_{5\text{c}\text{c}}\) values for the small bowel were 23.40 Gy and 25.69 Gy, respectively. No statistically significant differences were observed in the doses accumulated on the first or last fraction for the adaptive workflow, with results consistent with the single adaptive fractions. In contrast, accumulated doses in the IGRT workflow showed significant variations mitigating the high dose constraint, nevertheless, more than half of the patients still did not meet clinical requirements.Conclusions MRgART for short-course rectal cancer treatments ensures that the dose delivered matches each fraction of the planned dose and the results are confirmed by the dose accumulation process, which therefore seems redundant. In contrast, IGRT may lead to target dose discrepancies and non-compliance with organs at risk constraints and dose accumulation can still highlight notable dosimetric differences.

Publisher

Springer Science and Business Media LLC

Reference29 articles.

1. Rebecca L, Siegel ANG, Ahmedin J. Cancer Statistic 2024. CA: A Cancer Journal for Clinicians 2024; 74 (1): 12–49.

2. Cancer incidence and mortality in China, 2022. Zhonghua Zhong Liu Za Zhi (All-China Federation of Trade Unions);Zheng R,2024

3. Overview of Radiation Therapy for Treating Rectal Cancer;Bong Hyeon K;Annals Coloproctology,2014

4. van de Velde CJBP, Borras JM, Coebergh JW, Cervantes A, Blomqvist L. EURECCA colorectal: Multidisciplinary management: European consensus conference colon & rectum. European Journal of Cancer. 2014; 50 (1): 1.e1-1.e34.

5. Short-course radiotherapy followed by chemotherapy before total mesorectal excision (TME) versus preoperative chemoradiotherapy, TME, and optional adjuvant chemotherapy in locally advanced rectal cancer (RAPIDO): a randomised, open-label, phase 3 trial;Bahadoer R;Lancet Oncol,2020