In silico comparison of the dosimetric impacts of a greater omentum spacer for abdominal and pelvic tumors in carbon-ion, proton and photon radiotherapy

Author:

Yamada Masayoshi,Sato Hiraku,Ieko Yoshiro,Miyasaka Yuya,Kanai Takayuki,Yano Natsuko,Ono Takashi,Akamatsu Hiroko,Harada Mayumi,Ichikawa Mayumi,Teranishi Yasushi,Kikuchi Yasuhiro,Nemoto Kenji

Abstract

Abstract Purpose The purpose of this study was to compare carbon-ion (C-ion), proton and photon radiotherapy (RT) plans with regard to dose reduction of the gastrointestinal (GI) tract by using a greater omentum spacer (GO spacer). Methods We retrospectively retrieved data for ten patients who received the GO spacer as surgical spacer placement for abdominal and pelvic tumors. Simulation plans were created on pre-spacer Computed Tomography (CT) and post-spacer CT for C-ion RT, proton RT and photon RT to compare the dose of the GI tract. The plans were normalized so that at least 95% of the planning target volume (PTV) received 70 Gy (relative biological effectiveness equivalent) delivered in 35 fractions. All plans were created with the lowest possible dose to the GI tract under conditions that meet the dose constraints for the PTV and spinal cord (maximum dose < 45 Gy). The part of the GI tract to be evaluated was defined as that most adjacent to the PTV. C-ion RT plans and proton RT plans were calculated by a spot scanning technique, and photon RT plans were calculated employing by fixed-field intensity-modulated radiation therapy. Results D2 cc and V10–70 of the GI tract were significantly lower on post-spacer plans than on pre-spacer plans for all three RT modalities. Regarding post-spacer plans, D2 cc of the GI tract was significantly lower on C-ion RT plans and proton RT plans than on photon RT plans (C-ion vs photon p = 0.001, proton vs photon p = 0.002). However, there was no significant difference between C-ion RT plans and proton RT plans for D2 cc of the GI tract (C-ion vs proton p = 0.992). In the photon RT plan for one patient, D2 cc of the GI tract did not meet < 50 Gy. Conclusions The GO spacer shows a significant dose reduction effect on the GI tract.

Funder

Japan Agency for Medical Research and Development

Publisher

Springer Science and Business Media LLC

Subject

Radiology Nuclear Medicine and imaging,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3