Prediction of the minimum spacer thickness required for definitive radiotherapy with carbon ions and photons for pelvic tumors: an in silico planning study using virtual spacers

Author:

Yamada Masayoshi1,Miyasaka Yuya2,Kanai Takayuki1,Souda Hikaru2,Uematsu Ken1,Matsueda Rei1,Yano Natsuko1,Kawashiro Shohei1,Akamatsu Hiroko1,Harada Mayumi1,Hagiwara Yasuhito1,Ichikawa Mayumi1,Sato Hiraku1,Nemoto Kenji1

Affiliation:

1. Department of Radiation Oncology, Yamagata University Faculty of Medicine, 2-2-2, Iida-Nishi, Yamagata 990-9585, Japan

2. Department of Heavy Particle Medical Science, Yamagata University Faculty of Medicine, 2-2-2, Iida-Nishi, Yamagata 990-9585, Japan

Abstract

Abstract We aimed to predict the minimum distance between a tumor and the gastrointestinal (GI) tract that can satisfy the dose constraint by creating simulation plans with carbon-ion (C-ion) radiotherapy (RT) and photon RT for each case assuming insertion of virtual spacers of various thicknesses. We enrolled 55 patients with a pelvic tumor adjacent to the GI tract. Virtual spacers were defined as the overlap volume between the GI tract and the volume expanded 7–17 mm from the gross tumor volume (GTV). Simulation plans (70 Gy in 35 fractions for at least 95% of the planning target volume [PTV]) were created with the lowest possible dose to the GI tract under conditions that meet the dose constraints of the PTV. We defined the minimum thickness of virtual spacers meeting D2 cc of the GI tract <50 Gy as ‘MTS’. Multiple regression was used with explanatory variables to develop a model to predict MTS. We discovered that MTSs were at most 9 mm and 13 mm for C-ion RT and photon RT plans, respectively. The volume of overlap between the GI tract and a virtual spacer of 14 mm in thickness (OV14)-PTV was found to be the most important explanatory variable in the MTS prediction equation for both C-ion and photon RT plans. Multiple R2 values for the regression model were 0.571 and 0.347 for C-ion RT and photon RT plans, respectively. In conclusion, regression equations were developed to predict MTS in C-ion RT and photon RT.

Publisher

Oxford University Press (OUP)

Subject

Health, Toxicology and Mutagenesis,Radiology, Nuclear Medicine and imaging,Radiation

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3