Diagnostic performance of CareStart™ malaria HRP2/pLDH test in comparison with standard microscopy for detection of uncomplicated malaria infection among symptomatic patients, Eastern Coast of Tanzania

Author:

Bwire George M.,Ngasala Billy,Kilonzi Manase,Mikomangwa Wigilya P.,Felician Fatuma F.,Kamuhabwa Appolinary A. R.

Abstract

Abstract Background CareStart™ malaria HRP2/pLDH (Pf/pan) combo test is one of the several rapid diagnostic tests (RDT) approved for diagnosis of malaria at the point of care in Tanzania. However, there are limited studies on the diagnostic performance of RDT after wide scale use in primary health care facilities in Tanzania. Therefore, this study was carried out to determine the diagnostic performance of RDT when compared with blood smear (BS) microscopy as a reference standard. Methods A cross-sectional study was conducted between March and August 2019 at Kibiti Health Centre, Pwani region, Tanzania. Blood samples for malaria tests were collected from patients with malaria symptoms. Diagnostic performance parameters of RDT, i.e. sensitivity, specificity, positive and negative likelihood ratios (LR+/−), diagnostic accuracy and predictive values were determined using contingency table. An agreement between RDT and microscopy was statistically determined by Cohen’s kappa test. Results Of 980 patients screened, 567 (57.9%) were found to be malaria positive by RDT, whereas 510 patients (52%) were positive by microscopy. Of the 510 microscopy-positive patients, 487 (95.5%) were infected with Plasmodium falciparum. The geometric mean parasite density was 2921parasites/µl, whereas majority (68.6%) of patients had parasite density greater than 10,000/µl. The sensitivity, specificity, positive and negative predictive values of CareStart™ were 99.8%, 87.6%, 89.8%, and 99.8%, respectively. The LR+ and LR− were 8.0 and 0.002, respectively. The diagnostic accuracy was 0.5. There was a strong agreement between the results obtained using CareStart™ and BS microscopy (kappa = 0.863, P < 0.0001). Conclusion CareStart™ malaria HRP2/pLDH (Pf/pan) had high sensitivity and strong agreement with microscopy results. However, moderate specificity of RDT resulted in a substantial number of patients with false positive malaria test. Wherever available, microscopy should be used to confirm RDT test results.

Funder

Swedish International Development Cooperation Agency (Sida), Sweden through Muhimbili University of Health and Allied Sciences

Publisher

Springer Science and Business Media LLC

Subject

Infectious Diseases,Parasitology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3