Abstract
Abstract
Background
The aim of this study was to evaluate the distal movement, vertical movement, distal tipping and crown buccal torque of maxillary molars after the completion of distalization by comparing the predicted movement with the achieved movement using palatal rugae registration.
Methods
The study included 22 clear aligner patients (7 males and 15 females), and 79 molars were measured. Two digital models were generated before treatment and after molar distalization and were superimposed after selecting the palatal rugae area for registration in GOM inspect suite software 2022 (GOM; Braunschweig, Germany). The predicted and achieved movements of molar distalization, intrusion, distal tip and crown buccal torque were measured and compared.
Result
The achieved distalization (1.25 ± 0.79 mm vs. 2.17 ± 1.03 mm, P < 0.001; 1.41 ± 1.00 mm vs. 2.66 ± 1.15 mm, P < 0.001), intrusion (0.47 ± 0.41 mm vs. 0.18 ± 0.54 mm, P < 0.01; 0.58 ± 0.65 mm vs. 0.10 ± 1.12 mm, P < 0.01), distal tip (5.30 ± 4.56° vs. 1.53 ± 2.55°, P < 0.001; 4.87 ± 4.50° vs. − 1.95 ± 4.32°, P < 0.001) and crown buccal torque (1.95 ± 4.18° vs. − 1.15 ± 4.75°, P < 0.001; 0.43 ± 4.39° vs. − 4.27 ± 6.42°, P < 0.001) were significantly different from the predicted values in the two groups (first molar, second molar). Significant regression relationships were found between the achieved distal movement and deviational intrusion (R2 = 0.203, P < 0.0001), distal tip (R2 = 0.133, P < 0.001) and crown buccal torque (R2 = 0.067, P < 0.05). There was a significant correlation between the deviational movements of intrusion and the distal tip (R = 0.555, P < 0.0001).
Conclusion
Approximately 2 mm maxillary molar distalization was achieved in this study. Deviational movement of intrusion, distal tip and crown buccal torque beyond the clear aligner virtual design appeared to a certain degree after distalization. Thus, more attention should be given to molar intrusion and distal tip and crown buccal torque as the designed distalization increases.
Publisher
Springer Science and Business Media LLC
Reference36 articles.
1. Lione R, Franchi L, Lagana G, Cozza P. Effects of cervical headgear and pendulum appliance on vertical dimension in growing subjects: a retrospective controlled clinical trial. Eur J Orthod. 2015;37(3):338–44.
2. Clemmer EJ, Hayes EW. Patient cooperation in wearing orthodontic headgear. Am J Orthod Dentofac Orthop. 1979;75(5):517–24.
3. Sahm G, Bartsch A, Witt E. Reliability of patient reports on compliance. Eur J Orthod. 1990;12(4):438–46.
4. Nanda RS, Kierl MJ. Prediction of cooperation in orthodontic treatment. Am J Orthod Dentofac Orthop. 1992;102(1):15–21.
5. Kinzinger G, Syrée C, Fritz U, Diedrich P. Molar distalization with different pendulum appliances: in vitro registration of orthodontic forces and moments in the initial phase. J Orofac Orthop/Fortschritte der Kieferorthopädie. 2004;5(65):389–409.
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献