Author:
Juenemann Martin,Yeniguen Mesut,Schleicher Nadine,Blumenstein Johannes,Nedelmann Max,Tschernatsch Marlene,Bachmann Georg,Kaps Manfred,Urbanek Petr,Schoenburg Markus,Gerriets Tibo
Abstract
Abstract
Background
Cerebral air microembolization (CAM) is a frequent side effect of diagnostic or therapeutic interventions. Besides reduction of the amount of bubbles, filter systems in the clinical setting may also lead to a dispersion of large gas bubbles and therefore to an increase of the gas–liquid-endothelium interface. We evaluated the production and application of different strictly defined bubble diameters in a rat model of CAM and assessed functional outcome and infarct volumes in relation to the bubble diameter.
Methods
Gas emboli of defined number and diameter were injected into the carotid artery of rats. Group I (n = 7) received 1800 air bubbles with a diameter of 45 μm, group II (n = 7) 40 bubbles of 160 μm, controls (n = 6) saline without gas bubbles; group I and II yielded the same total injection volume of air with 86 nl. Functional outcome was assessed at baseline, after 4 h and 24 h following cerebral MR imaging and infarct size calculation.
Results
Computer-aided evaluation of bubble diameters showed high constancy (group I: 45.83 μm ± 2.79; group II: 159 μm ± 1.26). Animals in group I and II suffered cerebral ischemia and clinical deterioration without significant difference. Infarct sizes did not differ significantly between the two groups (p = 0.931 u-test).
Conclusions
We present further development of a new method, which allows reliable and controlled CAM with different bubble diameters, producing neurological deficits due to unilateral cerebral damage. Our findings could not display a strong dependency of stroke frequency and severity on bubble diameter.
Publisher
Springer Science and Business Media LLC
Subject
Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine
Reference35 articles.
1. Gupta R, Vora N, Thomas A, Crammond D, Roth R, Jovin T, Horowitz M: Symptomatic cerebral air embolism during neuro-angiographic procedures: incidence and problem avoidance. Neurocrit Care. 2007, 7: 241-246. 10.1007/s12028-007-0041-9.
2. Gerriets T, Schwarz N, Sammer G, Baehr J, Stolz E, Kaps M, Kloevekorn W-P, Bachmann G, Schönburg M: Protecting the brain from gaseous and solid micro-emboli during coronary artery bypass grafting: a randomized controlled trial. Eur Heart J. 2010, 31: 360-368. 10.1093/eurheartj/ehp178.
3. Muth CM, Shank ES: Gas embolism. N Engl J Med. 2000, 342: 476-482. 10.1056/NEJM200002173420706.
4. Bove AA, Hallenbeck JM, Elliott DH: Circulatory responses to venous air embolism and decompression sickness in dogs. Undersea Biomed Res. 1974, 1: 207-220.
5. Butler BD, Hills BA: Transpulmonary passage of venous air emboli. J Appl Physiol. 1985, 59: 543-547.