Author:
Huang Huan-lei,Xie Xu-jing,Fei Hong-wen,Xiao Xue-jun,Liu Jing,Zhuang Jian,Lu Cong
Abstract
Abstract
Background
Artificial chordae replacement is an effective technique for mitral valve repair, however, it is difficult to accurately determine the length of artificial chordae. This study aimed to assess the reliability and accuracy of real-time three-dimensional transesophageal echocardiography (TEE) to predict the length of artificial chordae preoperatively.
Methods
From December 2008 to December 2010, 48 patients with severe mitral regurgitation successfully underwent mitral valve repair using artificial chordae replacement. The patients were divided into a TEE pre-measurement group (n = 26) and a direct measurement group (n = 22), according to the method used to determine the length of artificial chordae. Cardiopulmonary bypass time, aortic cross-clamp time, and the recurrence rate of moderate or severe mitral regurgitation were compared between the two groups.
Results
There were no operative deaths in either group. The mean cardiopulmonary bypass time was 113.0 ± 18.7 min and 127.0 ± 28.9 min (p < 0.05), and the aortic cross-clamp time was 70.0 ± 16.6 min and 86.0 ± 20.7 min (p < 0.05) in the TEE pre-measurement group and direct measurement group, respectively. The difference between the pre-measured artificial chordal length and actual constructed artificial chordal length was not significant in the TEE pre-measurement group (p > 0.05). Although the difference in the incidence of moderate or severe mitral regurgitation between the two groups was not significant (p > 0.05), the incidence in the TEE pre-measurement group (3.8%) was lower than that in the direct measurement group (18.2%).
Conclusions
Real-time three-dimensional transesophageal echocardiography can accurately predict the length of artificial chordae required for mitral valve repair, and shortens cardiopulmonary bypass time and aortic cross-clamp time while improving the results of mitral valve repair.
Publisher
Springer Science and Business Media LLC
Subject
Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine
Reference28 articles.
1. Carpentier A: Cardiac valve surgery–the "French correction". J Thorac Cardiovasc Surg. 1983, 86: 323-337.
2. Adams DH, Kadner A, Chen RH: Artificial mitral valve chordae replacement made simple. Ann Thorac Surg. 2001, 71: 1377-1378. 10.1016/S0003-4975(00)02184-6. discussion 1378–1379
3. Rankin JS, Orozco RE, Addai TR, Rodgers TL, Tuttle RH, Shaw LK, Glower DD: Several new considerations in mitral valve repair. J Heart Valve Dis. 2004, 13: 399-409.
4. Seeburger J, Falk V, Borger MA, Passage J, Walther T, Doll N, Mohr FW: Chordae replacement versus resection for repair of isolated posterior mitral leaflet prolapse: a egalite. Ann Thorac Surg. 2009, 87: 1715-1720. 10.1016/j.athoracsur.2009.03.003.
5. Frater RW, Vetter HO, Zussa C, Dahm M: Chordal replacement in mitral valve repair. Circulation. 1990, 82: IV125-IV130.
Cited by
12 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献